Note
For UL Listed installations,
the Siren Timeout must be
set to 4 minutes or more.
¾To set the Siren Timeout:
With the display showing SIREN TIMEOUT nn MINUTES (current setting), enter the desired
time value (1–30). The display flashes the entered setting. Press # and the display show the
new setting.
Sleep Time (Timers—Partition 1-2)
(partition 1: 0314, partition 2: 0324)
(Default = 22:00 [10:00 pm.]) This setting determines the start time of a 10 hour window during
which trouble beeps are suppressed. The initial occurrence of an event that causes trouble beeps
within this window will not sound trouble beeps until the Sleep Time window expires. If trouble
beeps from a previous event are due to be restarted during the sleep time window, they will be
restarted one hour prior to Sleep Time.
¾
To set the Sleep Time:
With the display showing SLEEP TIME hh:mm (current setting), enter the desired time value
(00:00-23:50 using 10 minute intervals). The display flashes the entered setting. Press # and
the display show the new setting.
Light Control Menu
Note
For light control to work,
X-10 Powerhouse Lamp
Modules must be installed at
desired lamps.
The LIGHT CONTROL menu lets you set up light activation for a specific partition.
The following describes how to program the light control settings that appear under
PARTITION 1
and
PARTITION 2.
Entry Lights (Light Control—Partition 1-2)
(partition 1: 0400, partition 2: 0410)
Note
X-10 Lamp Modules set to 1
always turn on during the
entry and exit delays.
X-10 Lamp Modules set to 2
always flash the arming level
when arming the system.
For example, lights flash two
times when arming to STAY
(level 2), and three times
when arming to AWAY (level
3).
(Default = none) This setting determines which X-10 controlled lights turn on during entry and
exit delays.
¾
To set the Entry Lights:
1. With the desired partition selected, press #. The display shows ENTRY LIGHTS nnnnnnn (cur-
rent setting).
2. Enter all the desired light numbers (3–9 based on the UNIT dial setting on each X-10 Lamp
Module). The display flashes the entered setting(s). Press # and the display shows the new
setting(s).
¾
To delete Entry Lights:
Enter any light number that appears on the display, then press #. The number disappears
from the display.
House Code (Light Control—Partition 1, 2)
(partition 1: 0401, partition 2: 0411)
(Defaults: partition 1 = 01-B; partition 2 = 02-C) This setting enables X-10 controlled lights to
work in a selected partition without interfering with the X-10 controlled lights of the other parti-
tion.
After setting the panel house code for each partition, you must set the X-10 controlled lights for
that partition to the same house code. The letter that appears automatically after the house code
number indicates the necessary HOUSE dial setting for X-10 modules in that partition.
¾
To set the House Code:
1. With the desired partition selected, press A or B until the display shows HOUSE CODE nn-x
(current setting).
2. Enter the desired number (1–255). The display flashes the entered number. Press # and the
display shows the new house code.
Touchpad Options Menu
The TOUCHPAD OPTIONS menu lets you set up touchpad panic and arming operation. The follow-
ing section describes the touchpad option settings that appear under GLOBAL.
Latchkey Zones (Touchpad Options—Global)
(0500)
(Default = none) This setting defines the range of keychain touchpads that will function as a
latchkey user. The value entered in this section can be any valid zone number. When a zone num-
ber is entered, all zones at or below that zone number will function as a latchkey user. For exam-