Alarm Verify (Reporting—Partition 1-2)
(partition 1: 06108, partition 2: 06208)
(Default = off) This setting determines whether the panel reports to the central monitoring station
after a single sensor or zone trip (off) or waits for a second trip before reporting (on).
This setting affects sensors/zones in groups 10 through 20. If Alarm Verify is set to on, group 18
responds the same as group 17 (see “Appendix B, Table B1 “Sensor Group Characteristics”).
Note
For UL Listed installations,
Alarm Verify must be set to
off.
¾To turn Alarm Verify off or on:
With the display showing ALARM VERIFY OFF/ON (current setting), press 1 (off) or 2 (on).
The display flashes the entered setting. Press # and the display shows the new setting.
System Tamper (Reporting—Partition 1-2)
(partition 1: 06109, partition 2: 06209)
(Default = off) This setting determines how the panel handles possible tamper situations. When
this feature is on, the panel reacts in the following two ways:
• The system goes into alarm if several attempts are made to disarm the system with incorrect
access codes (40 consecutive keypresses).
• The panel reports to the central station if a bus device stops communicating with the panel.
Note
For UL Commercial Listed
installations (UL 1610), Sys-
tem Tamper must be set to
on.
¾To change the System Tamper setting:
With the display showing SYSTEM TAMPER OFF/ON (current setting), press 1 (off) or 2 (on).
The display flashes the entered setting. Press # and the display shows the new setting.
Siren Options Menu
The SIREN OPTIONS menu lets you set up siren operation and supervision.
The following describes how to program the siren option settings that appear under
GLOBAL
Immediate Beeps (Siren Options—Global)
(0700)
(Default = off) This setting determines whether the panel activates trouble beeps as soon as a
wireless device supervisory condition is detected (on), or if the panel waits until “supervisory
time” to activate trouble beeps (off). (Refer to
TIMERS—GLOBAL—SUPERVISORY TIME).
Note
For UL Listed installations,
this feature must be on.
¾To turn Immediate Beeps off or on:
With the display showing IMMEDIATE BEEPS OFF/ON (current setting), press 1 (off) or 2 (on).
The display flashes the entered setting. Press # and the display shows the new setting.
Disable Trouble Beeps (Siren Options—Global)
(0701)
(Default = off) When this setting is on, the panel will not beep to alert users of wireless device
supervisory trouble.
Note
For UL Listed installations,
Disable Trouble Beeps must
be set to off.
¾To turn Disable Trouble Beeps off or on:
With the display showing DISABLE TR BEEPS OFF/ON (current setting), press 1 (off) or 2 (on).
The display flashes the entered setting. Press # and the display shows the new setting.
UL 98 Options (Siren Options—Global)
(0702)
Note
For UL Listed installations,
this feature must be on.
(Default = off) This setting determines whether the panel complies with UL 98 requirements (4-
hour trouble beep restart, 4-hour backup battery test, 4-hour smoke (group 26) zone supervisory).
¾
To turn UL 98 Options off or on:
With the display showing UL 98 OPTIONS OFF/ON (current setting), press 1 (off) or 2 (on).
The display flashes the entered setting. Press # and the display shows the new setting.
Note
To supervise wireless sirens,
Concord hardwire panels
must include a SuperBus
2000 RF Receiver. For all
Concord panels, the siren
must be learned into sensor
group 33 for the system to
process radio signals from
wireless sirens.
SWS Supv Code (Siren Options—Global)
(0703)
(Default = 3) This setting determines the system house code number used for supervising wire-
less sirens.
Supervised Wireless Sirens receive signals from the panel through the existing electrical wiring.
If sirens fail to receive or process these signals, the siren transmits a wireless signal to the panel/
receiver.