Setting Device Address on SuperBus 2000 Devices
When the panel is powered up it automatically assigns device addresses and unit numbers to
SuperBus 2000 devices, enabling the panel and module to communicate.
Note
The panel cannot be used
on a digital or PBX phone
line. These systems are
designed for digital type
devices only, operating any-
where from 5 volts DC and
up. The panel uses an ana-
log modem and does not
have a digital converter,
adapter, or interface to oper-
ate through such systems.
Installing an RJ-31X Phone Jack (13-081)
Use the following guidelines when installing an RJ-31X phone jack for system control by phone
and central station monitoring.
Locate the RJ-31X jack (CA-38A in Canada) no further than five feet from the panel.
The panel must be connected to a standard analog (loop-start) phone line, that provides 48
volts DC (on-hook or idle) which increases to 89 to 105 volts DC (ring voltage).
For full line seizure, install an RJ-31X phone jack on the premises phone line so the panel is
ahead of all phones and other devices on the line. This allows the panel to take control of the
phone line when an alarm occurs, even if the phone is in use or off-hook.
Note
Connecting the panel to an
analog line off the phone
switch places the panel
ahead of the phone system,
preventing panel access
from phones on the pre-
mises. However, the panel
can still be accessed from
off-site phones.
If an analog line is not available, contact a telecommunications specialist and request an ana-
log line off the phone switch (PBX mainframe) or a 1FB (standard business line).
¾
To connect a phone line to the panel using an RJ-31X/CA-38A jack:
1. Run a 4-conductor cable from the TELCO protector block to the jack location (see A in Fig-
ure 34).
2. Connect one end of the cable to the jack (see B in Figure 34).
3. At the TELCO protector block, remove the premises phone lines from the block and splice
them to the black and white (or yellow) wires of the 4-conductor cable (see C in Figure 34).
4. Connect the green and red wires from the 4-conductor cable to the TIP (+) and RING (-)
posts on the block (see D in Figure 34).
5. Check the phones on the premises for dial tone and the ability to dial out and make phone
calls. If phones do not work correctly, check all wiring and correct where necessary. Proceed
to the “Troubleshooting” section of this manual if problems persist.
Connecting the Phone Line to the Panel with a DB-8 Cord
After installing the RJ-31X jack, you are ready to connect the phone line to the panel. A DB-8
cord (not included) uses a plug at one end for connecting to the RJ-31X module and flying leads
on the other end for panel terminal connections.
¾
To connect the DB-8 cord to the panel terminals and RJ-31X jack:
1. Connect the green, brown, gray, and red flying leads from the DB-8 cord to panel terminals
24, 25, 26, and 27 (see Figure 35).
2. Insert the DB-8 cord’s plug into the RJ-31X (see Figure 35).
3. Check the phones on the premises for dial tone and the ability to dial out and make phone
calls. If phones do not work correctly, check all wiring and correct where necessary. Proceed
to the “Troubleshooting” section of this manual if problems persist.
6
0 7 3 4 G 8 4 D . D S F
R I N G
( - )
T I P
( + )
A
B
C
D
2 5
2 6 2 7
6 0 7 3 4 G 8 6 D . D S F
2 4
Gry
Brn
Red
Grn
Jack
RJ-31X
Black
Green
Red
White
(or Yellow)
(or Yellow)
White
Red
Black
Green
Green
Red
TELCO
Protector Block
RJ-31X
Phone
Line
Wire
Run
Lines From
Phones On
Premises
Brn GryGrn Red
Red
Gray
Brown
Green
Brn Gry
Grn Red
RJ-31X
Jack
TELCO
House
Figure 34. Installing an RJ-31X Phone Jack
Figure 35. Connecting the DB-8 Cord to the
Panel Terminals and RJ-31X Jack