1. With the display showing AUDIO VERIFY OFF/ON, press A or B until the display shows
ACCESS CODE nnnn (current code).
2. Press D to delete.
Accessory Modules Menu
The ACCESSORY MODULES menu gives you access to the following menus:
BUS DEVICES—this menu lets you read bus device unit numbers, assign bus devices to a par-
tition, and configure other features associated with a specific bus device.
SNAPCARDS—this menu lets you set the configuration number for each SnapCard output,
assign SnapCard outputs to a partition, and name the SnapCard outputs.
The following procedure describes how to program the settings that appear under ACCESSORY
MODULES—BUS DEVICES
.
Note
Most settings under ACCES-
SORY MODULES—BUS
DEVICES have no shortcut
numbers.
Unit - ID (Acc. Modules—Bus Devices)
(10000 thru 10015)
(Default = none) This menu lets you identify all connected bus devices, view each Unit Number,
view the Device ID number, and configure other settings based on a specific device. This menu
also lets you delete learned bus devices.
¾
To identify bus device Unit and ID:
1. With the display showing BUS DEVICES, press #. The display shows the bus Unit Number and
the 8-digit Device ID number. For example:
UNIT - ID 0—02110185. Where 0 is the Unit Num-
ber and 02110185 is the Device ID number.
Note
To help identify bus devices,
the 8-digit Device ID number
is also located on a label on
each SuperBus 2000 device.
2. Press A or B to identify all other bus Unit Numbers (0–15) and Device ID numbers.
¾
To delete learned Unit Numbers:
1. With the display showing BUS DEVICES, press #. The display shows the bus device set to
Unit Number 0.
2. Press A or B until the bus device Unit Number you want to delete is displayed.
3. Press D. The display changes the Unit Number to
NONE.
Device ID (Acc. Modules—Bus Devices—Unit ID—Change ID)
(Default = none) This menu lets you change the bus device ID number when replacing a defec-
tive bus device.
¾
To change a Device ID:
1. With the display showing the desired bus device, press # + #. The display shows DEVICE ID
(current ID).
2. Enter the ID of the new bus device. The display flashes the entered selection. Press # and the
display shows the new setting.
3. Exit programming mode.
4. Remove AC and battery power from the panel.
5. Replace the defective bus device with a new one.
6. Apply AC and battery power to the panel.
Partition Assign (Acc. Modules—Bus Devices—Unit ID—Device Partition)
(Default = 1) This menu lets you assign bus devices to work in the desired partition.
Note
SuperBus 2000 8Z Input
Modules, SuperBus 2000
4-Relay Output Modules,
and SuperBus 2000 RF
Receivers are not assigned
to partitions.
¾To assign bus devices to partitions:
1. With the display showing the desired bus device, press #.
2. Press A or B until the display shows DEVICE PTN and then press #. The display shows PARTI-
TION ASSIGN n.
3. Press 1 or 2 to select the desired partition. The display flashes the entered selection. Press #
and the display shows the new setting.
Output Programming (Acc. Modules—Unit ID—Outputs)
Use these settings to program the output points of any installed SuperBus 2000 Hardwire Output
Module. The installer programs a HOM output point into the Concord security panel by entering
three kinds of information.
Partition -the system partition (1 or 2).
Trigger - the event that activates the output point. Trigger events can be partition alarms,
trouble conditions, open sensors, etc. (see Appendix B: Reference Tables).

Table of Contents