50
• Response - how the output responds when trigger event occurs (see Appendix B: Reference
Tables).
This section describes how to program each of the HOM output point configurations into the
security panel. The point configuration number is tttrr, where ttt is the trigger number and rr is
the response number.
Note
HOM output points cannot
be configured for user con-
trol. Only the onboard and
SnapCard outputs can be
configured for user control.
1. With the display showing the desired bus device, press #.
2. Press A or B until the display shows
OUTPUTS.
3. Press #. The display shows
OUTPUT 1.
4. Press A or B to select an output, then press #. The display shows PARTITION ASSIGN 1.
5. Press 1 or 2 to select the desired partition assignment for this relay. The display flashes the
entered setting. Press # and the display shows the new setting.
6. Press A or B. The display shows
CONFIGURATION tttrr (current setting).
7. Enter the desired 5-digit configuration number for this relay. The display flashes the entered
setting. Press # and the display shows the new setting.
8. Press # and repeat steps 4 through 8 until all outputs are programmed
Status Beeps (Acc. Modules—Bus Device—Unit ID—Keypad Options)
(Default = on) This setting determines whether or not the selected touchpad sounds status beeps.
Each touchpad can be set individually.
This feature is usually turned off for a touchpad that is located in or near bedrooms, to avoid dis-
turbing sleeping persons.
Note
For UL Listed installations,
Status Beeps must be set to
on.
¾To turn touchpad Status Beeps on or off:
1. With the display showing the desired touchpad, press # then A or B until the display shows
KEYPAD OPTIONS.
2. Press # and the display shows STATUS BEEPS OFF/ON (current setting).
3. Press 1 (off) or 2 (on) to select the desired setting. The display flashes the entered selection.
Press # and the display shows the new setting.
Key Beeps (Acc. Modules—Bus Devices—Unit ID—Keypad Options)
(Default = on) This setting determines whether or not selected touchpads beep when their buttons
are pressed.
This feature is usually turned off for a touchpad that is located in or near bedrooms, to avoid dis-
turbing sleeping persons.
¾
To turn Key Beeps on or off:
1. With the display showing the desired touchpad, press # then A or B until the display shows
KEYPAD OPTIONS. Next, press # then A or B until the display shows KEY BEEPS OFF/ON (cur-
rent setting).
2. Press 1 (off) or 2 (on) to select the desired setting. The display flashes the entered selection.
Press # and the display shows the new setting.
Freeze Temp (Acc. Modules—Bus Devices—Unit ID—Energy Options)
(Default = 42°F) This setting determines the temperature point that the Energy Saver Module
detects a potential freeze (heating failure) condition. The adjustable range is from 40° to 90°F.
¾
To change the Freeze Temp setting:
1. With the display showing the desired bus device press #, then A or B until the display shows
ENERGY OPTIONS. Next, press # then A or B until the display shows FREEZE TEMP nn
DEGREES (current setting).
2. Enter the desired freeze temperature (40°–90° F). The display flashes the entered selection.
Press # and the display shows the new setting.
Temperature (Acc. Modules—Bus Devices—Unit ID—Energy Options)
(Default = none) This setting lets you adjust the Energy Saver Module (ESM) room temperature
setting to match the premises thermostat. The adjustable range is from 40°–90°F.
Note
To ensure accuracy, wait at
least 15 minutes before set-
ting the ESM temperature to
allow the ESM to warm or
cool to actual room tempera-
ture.
¾To change the ESM Temperature setting:
1. With the display showing the desired bus device press #, then A or B until the display shows
ENERGY OPTIONS. Next, press # and then A or B until the display shows TEMPERATURE nn
DEGREES
(current setting).
2. Enter the desired temperature (40°–90° F). The display flashes the entered selection. Press #
and the display shows the new setting.