Attach Schedules to Events Menu
The ATTACH SCHEDULES TO EVENTS menu lets you link the following system events to time
schedules:
Latchkey Opening—sends a report if system is disarmed within the attached time schedule.
Latchkey Closing—sends a report if system is armed within the attached time schedule.
Exception Opening—sends a report if system is not disarmed within the attached time
schedule.
Exception Closing—sends a report if system is not armed within the attached time sched-
ule.
Lights (19) activate X-10 controlled lights by the attached time schedule.
Outputs (16) allow users to attach onboard (1–2) and SnapCard outputs to a schedule.
ArmingAllows the user to arm the panel at the schedule start time.
Latchkey Reports (Attach Schedules To Events)
(060nn—Opening, 061nn—Closing where nn = Schedule number [0 to 15])
(Default = off) This setting lets you attach the Latchkey Opening report feature and the Latchkey
Closing report feature to time schedules.
¾
To Attach a Schedule to Latchkey Opening or Latchkey Closing:
1. Press A or B until the display shows ATTACH SCHEDULES TO EVENTS.
2. Press # then A or B until the display shows LATCHKEY OPENING OR LATCHKEY CLOSING.
3. Press # and the display shows SCHEDULE 00 OFF/ON (current setting). If you want a different
schedule, press A or B until the desired schedule appears.
4. Press 1 (off) or 2 (on). The display flashes the entered selection. Press # and the display
shows the new setting for the selected schedule.
Exception Reports (Attach Schedules To Events)
(062nn—Opening, 063nn—Closing, where nn = Schedule number [0 to 15])
(Default = off) This setting lets you attach the Exception Opening report feature and the Excep-
tion Closing report feature to time schedules.
¾
To Attach a Schedule to Exception Opening or Exception Closing:
1. Press A or B until the display shows ATTACH SCHEDULES TO EVENTS.
2. Press # then A or B until the display shows
EXCEPTION OPENING OR EXCEPTION CLOSING.
3. Press # and the display shows
SCHEDULE 00 OFF/ON (current setting). If you want a different
schedule, press A or B until the desired schedule appears.
4.
Press 1 (off) or 2 (on). The display flashes the entered selection. Press # and the display shows
the new setting for the selected schedule.
Lights (Attach Schedules To Events)
(064xnn where nn = Schedule number [0 to 15] and x = light number [1 to 9] minus 1)
(Default = off) This setting lets you attach light controls to a time schedule.
¾To Attach Schedules to Lights:
1. Press A or B until the display shows ATTACH SCHEDULES TO EVENTS.
2. Press # then A or B until the display shows LIGHTS. Press # to enter the LIGHTS menu.
3. Press A or B until the desired light appears.
4. Press # and the display shows
SCHEDULE 00 OFF/ON (current setting). If you want a different
schedule, press A or B until the desired schedule appears.
5. Press 1 (off) or 2 (on). The display flashes the entered selection. Press # and the display
shows the new setting for the selected schedule.
6. Repeat steps 3, 4, and 5 until all desired lights are attached to schedules.
Outputs (Attach Schedules To Events)
(065xnn where nn = Schedule number [0 to 15] and x = output number [1 to 6] minus 1)
(Default = off) This setting lets you attach outputs to a time schedule. Onboard outputs are 1–2,
SnapCard outputs are 3–6.
Note
Outputs can only be sched-
uled if text has been entered
in installer programming.
Only onboard and SnapCard
outputs can be scheduled.
¾To Attach Schedules to Outputs:
1. Press A or B until the display shows ATTACH SCHEDULES TO EVENTS.
2. Press # then A or B until the display shows
OUTPUTS. Press É to enter the OUTPUTS menu.
3. Press A or B until the desired output appears.
4. Press # and the display shows SCHEDULE 00 OFF/ON (current setting). If you want a different
schedule, press A or B until the desired schedule appears.