Connecting the AC Power Transformer
The panel must be powered by a plug-in stepdown transformer that supplies 24 VAC, 30 VA (60-
761) or 24 VAC, 50 VA (60-778).
For systems that include a Power Line Carrier card and Supervised Wireless Sirens, or X-10
Lamp Modules, the panel must be powered with the Line Carrier Power Transformer that sup-
plies 24 VAC, 30 VA (60-762) or 24 VAC, 50 VA (60-779). Connect the power transformer to the
panel as shown in Figure 36.
Powering Up the Panel
After connecting and wiring all devices to the panel, you are ready to apply AC and backup bat-
tery power to the panel.
¾
To power up the panel:
1. Connect the red and black battery leads (included with panel) to the lugs located on the panel
(see Figure 37).
2. Connect the other ends of the battery leads to the battery terminals (see Figure 37).
3. Plug the transformer into an outlet that is not controlled by a switch.
Alphanumeric touchpads display
************, then SCANNING BUS DEVICES, and finally a
date and time display.
Note
If alphanumeric touchpads
don’t display anything,
immediately unplug the
transformer and disconnect
the backup battery. Refer to
the “Troubleshooting” sec-
tion.
4. To permanently mount the transformer, unplug it and remove the existing screw securing the
AC outlet cover.
5. Hold the outlet cover in place and plug the transformer into the lower receptacle.
6. Use the screw supplied with the transformer to secure the transformer to the outlet cover.
Programming
the Panel
For on-site system programming, an alphanumeric touchpad is required.
Entering Program Mode
Entering program mode is done using an installer/dealer code (default = 4321). The system can
be put into program mode only when the system is disarmed.
Do not plug in the power transformer at this time. The panel must be powered up using
the sequence of steps described in the next section, “Powering Up the Panel.”
Caution
!
1
2
6 0 7 3 4 g 1 0 4 d . d s f
2 4 V A C
6 0 7 3 4 g 1 0 6 d . d s f
Panel Terminals
Backup Battery Connections
Battery
Red
Black
Red
Black
Figure 36. Connecting a Power Transformer
to the Panel Terminals
Figure 37. Connecting the Backup Battery
to the Panel
Use extreme caution when securing the transformer to a metal outlet cover. You could
receive a serious shock if a metal outlet cover drops down onto the prongs of the plug
while you are securing the transformer and cover to the outlet box.
Warning
!