24
Figure 39. Tier 1 Program Menus
Arrows pointing right represent pressing B to advance forward through the menus. Pressing A
moves through the menus in reverse.
The arrow below the
SYSTEM PROGRAMMING menu represents pressing # to advance to tier 2 pro-
gramming menus. Only when
SYSTEM PROGRAMMING is displayed can you advance to tier 2
menus (see Figure 40).
Figure 40. Tier 2 Program Menus
Again, arrows pointing right represent pressing B to advance forward through the menus. Press-
ing A moves through the menus in reverse.
Arrows below each menu represent pressing # to advance to those settings that pertain to that
menu. Only when a specific menu is displayed can you advance to those settings. For example,
from the
SENSORS menu pressing # gives you access to learning sensors, programming sensor
text, deleting sensors, and viewing/editing sensor programming. Settings in tier 2 menus can also
be accessed by entering shortcut numbers. See the section, “Programming Tier 2 Menu Items”
for complete details.
Programming Tier 1 Menu Items
This section guides you through programming tier 1 menu items as they appear in sequence. The
exact order you follow will depend on whether you’re installing a new system or changing pro-
gramming in an existing system.
Demo Kit Mode (System Programming)
(Default = off) This setting determines whether the panel is used for a standard installation (off)
or as a demo kit (on). When the Demo Kit option is on, only sensors learned into groups 01 and
03, duress code use, and phone test (8 + System Master Code + 2) will be reported. Turning on
this feature and performing a memory clear changes the following settings:
Partition 1 Master Code = 1000
Partition 2 Master Code = 2000
User Code 00 = 1001 (partition 1 code—can also be used to jump to partition 2)
User Code 01 = 1002 (partition 1 code—can also be used to bypass sensors)
User Code 02 = 2001 (partition 2 code—can also be used for remote or off-site access)
User Code 03 = 2002 (partition 2 code—can also be used to perform system tests)
#
A
B
A
B
A
B
A
B
B
*
Tier 1
Menu
System
Programming
To Tier 2
From Tier 2
Menus
Menus
Demo Kit
Off/On
Partition 1
Copy
Clear
Memory
Exit
Programming
Ready
#
A
B
A
B
A
B
A
B
A
B
*
6 0 7 3 4 g 3 1 0 d . d s f
#
*
#
*
#
*
#
*
#
A
B
A
B
A
B
A
B
A
B
*
#
*
#
*
#
*
#
*
#
A
B
A
B
*
#
*
Tier 2
Menu
Security Phones
Phone
Options
Timers
Light
Control
Touchpad
Options
Reporting
Siren
Options
Sensors
Audio
Verification
Accessory
Modules
Onboard
Options
To Security Menu
From Security Menu