¾To adjust status sound Volume:
1. Press A or B until the display shows OPTIONS, then press #.
2. Next, press A or B until the display shows
VOLUME n (current setting).
3.
Enter a setting from 0 (off) to 7 (loudest). The display flashes the entered selection. Press # and
the display shows the new setting.
Voice Chime (Options)
(044)
(Default = on) This setting determines whether speakers connected to the Phone Interface/Voice
Module announce perimeter sensor/zone numbers that are tripped when the Chime feature is on.
For example, “Sensor one open.”
Note
This menu appears only if a
Phone Interface/Voice Mod-
ule is connected to the
panel.
¾To turn Voice Chime off or on:
1. Press A or B until the display shows OPTIONS.
2. Press # then A or B until the display shows
VOICE CHIME OFF/ON (current setting).
3.
Press 1 (off) or 2 (on). The display flashes the entered selection. Press # and the display shows
the new setting.
Chime On Close (Options)
(045)
(Default = off) When this setting is on, the panel sounds a single chime when a perimeter door or
window is closed.
¾
To turn Chime On Close off or on:
1. Press A or B until the display shows OPTIONS.
2. Press # then A or B until the display shows
CHIME ON CLOSE OFF/ON (current setting).
3. Press 1 (off) or 2 (on). The display flashes the entered selection. Press # and the display
shows the new setting.
Set Up Schedules Menu
The SET UP SCHEDULES menu lets you set up time frames for light control and exception opening/
closing reports
. The system (all partitions) allows you to set up to 16 schedules (00–15).
Setting up schedules consists of setting a start and stop time for each schedule, then selecting
which days of the week the schedule will be active. You can also set up a rollover schedule,
which starts on one day and ends on another day. This saves programming time and leaves more
schedules available (in case they are needed later).
Rollover Schedule Example: To set up a schedule to rollover from Tuesday evening to Wednes-
day morning, set a schedule start time for 2200 (10:00
P.M.) and a stop time for 0500 (5:00 A.M.).
Set the schedule to turn on Tuesday. Because the stop time is set for morning, the system auto-
matically carries the schedule over to the next day.
If you use the same start and stop times described above and set the schedule to turn on Monday
through Friday, then one schedule will cover the entire week.
Note
If you are programming
schedules for your customer,
be sure to record the set-
tings in the User’s Manual
Set Up Schedules
(05XXY, where XX = schedule 00 thru 15 and Y = start [0]/stop[1] 0 thru 8—Monday thru
Sunday [2–8])
(Default = 00:00) This menu lets you set up start/stop times for each day of the week.
¾To set up a Time Schedule:
1. Press A or B until the display shows SET UP SCHEDULES.
2. Press # and the display shows
SCHEDULE 00. If you want a different schedule number, press
A or B until the desired schedule number appears.
3. Press # and the display shows START TIME hh:mm (current setting).
4. Enter the desired starting time (00:00–23:59). The display flashes the entered time. Press #
and the display shows
START TIME hh:mm (new setting).
5. Press B and the display shows STOP TIME hh:mm (current setting).
6. Enter the desired stop time (00:00–23:59). The display flashes the entered time. Press # and
the display shows
STOP TIME hh:mm (new setting).
7. Press B and the display shows MONDAY OFF/ON (current setting). To select a different day,
continue pressing B until the desired day appears.
8. Press 1 (off) or 2 (on). The display flashes the entered selection. Press # and the display
shows the new setting for the selected day.