Figure 19. Connecting an Interrogator 200 AVM to the Panel
Connecting Alphanumeric and Fixed Display Touchpads
Alphanumeric and Fixed Display touchpads use the same color-coded wire scheme. Connect the
touchpads to the panel power output and bus terminals as shown in Figure 20.
Installing SuperBus 2000 Modules
SuperBus 2000 modules can be installed inside the panel cabinet or away from the panel. Use the
following guidelines when installing modules inside the panel cabinet:
Up to 16 bus modules can be connected to the panel. (15 modules for the RF panel since
receiver counts as 1.)
Up to 3 of the SuperBus 2000 modules listed in Table 1 can be mounted inside the cabinet.
The panel includes two support standoffs you install to secure module backplates to the
panel (see Figure 22).
Note
Even if you don’t plan to
mount modules inside the
cabinet, install the support
standoffs for future use and
to avoid losing them.
Install the standoffs at the locations shown in Figure 22.
The cabinet has built-in mounting clips on the top and sides that module backplates slide
onto for mounting (see Figure 22).
87
4
+ 1 2 V
3
G N D
1 1
M I C
Panel Terminals
Black
Yellow
Splice
Cable Shield
Speaker
Run Separate
Wire Cables
As Shown
GND
+12V
A
BUS
B
SuperBus 2000
Fixed Display
Touchpad or
LCD Alphanumeric
Touchpads
+12V/Red
Bus A/Green
Bus B/White
GND/Black
Figure 20. Connecting Touchpads to the Panel
Panel Standoff
Panel End
Module End
Figure 21. Support Standoff