(3) Callback Silent—Same as Callback, except premises phones do not ring.
¾
To set Audio Mode:
1. With the display showing AUDIO VERIFY OFF/ON, press A or B until the display shows
AUDIO MODE nn (current setting).
2.
Enter the desired mode number (1–3). The display flashes the entered setting. Press # and the dis-
play shows the new setting.
Fire Shutdown (Audio Verification—Partition 1)
(0902)
(Default = off) This setting determines whether system sirens turn off during a fire alarm audio
session.
¾
To turn Fire Shutdown off or on:
1. With the display showing AUDIO VERIFY OFF/ON, press A or B until the display shows FIRE
SHUTDOWN OFF/ON (current setting).
2. Press 1 (off) or 2 (on). The display flashes the entered setting. Press # and the display shows
the new setting.
Silent Talkback (Audio Verification—Partition 1)
(0903)
(Default = off) This setting determines whether the central station operator can speak to persons
on the premises (on) or only listen (off) during a silent or duress alarm audio session.
¾
To turn Silent Talkback off or on:
1. With the display showing AUDIO VERIFY OFF/ON, press A or B until the display shows
SILENT TALKBACK OFF/ON (current setting).
2.
Press 1 (off) or 2 (on). The display flashes the entered setting. Press # and the display shows the
new setting.
Access Timeout (Audio Verification—Partition 1)
(0904)
(Default = 90 sec) If the Audio Mode is set to “Instant,” then this setting determines how much
time (30–300s, in 2-second increments) the central station operator has to enter the AVM access
code after the panel is accessed for an audio session.
¾
To change the Access Timeout:
1. With the display showing AUDIO VERIFY OFF/ON, press A or B until the display shows
ACCESS TIMEOUT nn SECS (current setting).
2.
Enter the desired time. The display flashes the entered setting. Press # and the display shows the
new setting.
Beep Delay (Audio Verification—Partition 1)
(0905)
(Default = 02 sec) This setting determines how long AVM access beeps are delayed (0–300s, in
2-second intervals) at the beginning of a 2-way audio session.
¾
To change the Beep Delay:
1. With the display showing AUDIO VERIFY OFF/ON, press A or B until the display shows BEEP
DELAY nn SECS
(current setting).
2. Enter the desired time. The display flashes the entered setting. Press # and the display shows
the new setting.
Access Code (Audio Verification—Partition 1)
(0906)
(Default = or none) This setting determines the code required to access the audio verification
module to start an audio session. If no code is programmed, pressing * starts an audio session.
¾
To change the Access Code:
1. With the display showing AUDIO VERIFY OFF/ON, press A or B until the display shows
ACCESS CODE nnnn (current code).
2. Enter the desired 4-digit access code. The display flashes the entered code. Press # and the
display shows the new setting.
¾
To delete an Access Code: