1. With the display showing USER CODES, press # and the display shows REGULAR USER CODES.
2. Press #
and the display shows USER nn (first available user number).
3. Press A or B to select the desired user number, then press #. The display shows
USER nn -
nnnn.
4. Press A or B until the display shows
DIRECT BYPASSING OFF/ON (current setting).
5. Press 1 (off) or 2 (on). The display flashes the entered setting. Press # and the display shows
the new setting.
Remote Access (User Codes—Reg. User Codes—User NN)
(030nn2 where nn=user number 00-59)
(Default = off) This setting determines whether or not the user can access the panel from a
remote phone (a phone located off the premises).
¾
To turn user code Remote Access off or on:
1. With the display showing USER CODES, press # and the display shows REGULAR USER CODES.
2. Press #
and the display shows USER nn (first available user number).
3. Press A or B to select the desired user number, then press #. The display shows
USER nn -
nnnn.
4. Press B until the display shows REMOTE ACCESS ON/OFF (current setting).
5. Press 1 (off) or 2 (on). The display flashes the entered setting. Press # and the display shows
the new setting.
Partition Jump (User Codes—Reg. User Codes—User NN)
(030nn3 where nn=user number 00-59)
(Default = off) This setting determines whether or not a specific user code can access one or both
partitions. When this is set to on, the user can access both partitions.
¾
To turn user code Partition Jump off or on:
1. With the display showing USER CODES, press # and the display shows REGULAR USER CODES.
2. Press #
and the display shows USER nn (first available user number).
3. Press A or B to select the desired user number, then press #. The display shows
USER nn -
nnnn.
4. Press B until the display shows
PARTITION JUMP OFF/ON (current setting).
5. Press 1 (off) or 2 (on). The display flashes the entered setting. Press # and the display shows
the new setting.
System Tests (User Codes—Reg. User Codes—User NN)
(030nn4 where nn=user number 00-59)
(Default = off) This setting determines whether or not a specific user code provides access to the
phone and sensor tests. Set this feature to “on” for all users who need to be able to conduct phone
and sensor tests.
¾
To turn user code System Tests off or on:
1. With the display showing USER CODES, press # and the display shows REGULAR USER CODES.
2. Press #
and the display shows USER nn (first available user number).
3. Press A or B to select the desired user number, then press #. The display shows
USER nn -
nnnn.
4. Press A or B until the display shows
SYSTEM TESTS OFF/ON (current setting).
5. Press 1 (off) or 2 (on). The display flashes the entered setting. Press # and the display shows
the new setting.
Latchkey Report (User Codes—Reg. User Codes—User NN)
(030nn5 where nn=user number 00-59)
(Defaults: 00–05 = on, 06–59 = off) This setting determines whether or not the user code causes
a latchkey report to be sent to a pager when the code is used to change arming levels.
¾
To assign the Latchkey Report attribute to user codes:
1. With the display showing USER CODES, press # and the display shows REGULAR USER
CODES
.
2. Press #
and the display shows USER nn (first available user number).
3. Press A or B to select the desired user number, then press #. The display shows
USER nn -
nnnn
.
4. Press A or B until the display shows
LATCHKEY OFF/ON (current setting).
5. Press 1 (off) or 2 (on). The display flashes the entered setting. Press # and the display shows
the new setting.