Concord
5
8 Supervised Hardwire Zones: Inputs for various hardwired detectors. Zone 8 can be set
up in programming to accept 2-wire smoke detectors.
Built-In SuperBus 2000 Receiver (60-792-01-95R only): Allows use of up to 16 or 32
319.5 MHz. crystal and/or SAW Learn Mode wireless sensors and touchpads. Also allows
supervision of Supervised Wireless Sirens.
Phone Line Connection: Allows panel to communicate with central monitoring station and/
or pagers.
SuperBus 2000 Touchpads
The following describes the different touchpads that can be used for system programming and
operation.
SuperBus 2000 Fixed Display Touchpad: Provides operation control and user-program-
ming access (not installer/dealer programming). Displays system messages and indicates
system status.
SuperBus 2000 2x16 LCD Touchpad: Provides complete system programming and opera-
tion control. Displays system messages that prompt users for information when needed and
indicates system status.
SuperBus 2000 2x20 LCD Touchpad: Provides complete system programming and opera-
tion control. Large display shows system messages that prompt users for information when
needed and indicates system status.
SuperBus 2000 2x20 VFD Touchpad: Provides complete system programming and opera-
tion control. Large fluorescent display shows system messages that prompt users for infor-
mation when needed and indicates system status.
SuperBus 2000 RF Receivers
These receivers expand system wireless zone capacity by 16, 32, or the maximum zones allowed
by the panel. The receivers are compatible with all 319.5 MHz. crystal and SAW Learn Mode
wireless sensors, touchpads, and Supervised Wireless Sirens. You may connect up to 4 receivers
to the panel.
Power Line Carrier Card
Adding this card (which requires that the panel be powered using a Power Line Carrier Trans-
former) adds the following capabilities to the system:
Allows the use of Supervised Wireless Sirens.
Allows the use of X10 Powerhouse Lamp Modules for light control and light activation dur-
ing alarms.
Phone Supervision Card
Adding this card allows the panel to check for the correct phone line voltage (partition 1 only),
upon dialing the central station/pager number. The panel can also be programmed to check the
phone line voltage automatically.
Supervised Wireless Siren
Supervised Wireless Sirens plug into any standard electrical outlet and produce status and alarm
sounds. The panel sends signals to the siren through the Power Line Carrier Card and Line Car-
rier Power Transformer, through the AC electrical wiring.
The siren has a built-in transmitter that is used for supervising with the panel. With the siren
transmitter learned into panel memory (panels with receivers), the siren can notify the panel if it
is unplugged, stops receiving panel signals, or has a low backup battery.
SuperBus 2000 Phone Interface/Voice Module
This module allows system access and control using touch-tone telephones, on- or off-site. The
module includes an output for a speaker that sounds system status and alarm voice messages.
SnapCards
The following SnapCards expand the system as described:
8Z Input SnapCard: Provides eight additional hardwire zone inputs, of which two are ded-
icated for using two wire smoke detectors.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Interlogix Concord Security System and is the answer not in the manual?

GE Interlogix Concord Security System Specifications

General IconGeneral
BrandGE Interlogix
ModelConcord Security System
CategorySecurity System
LanguageEnglish

Related product manuals