Concord
35
Phone Options Menu
The PHONE OPTIONS menu lets you set up system phone access and communications that affect
the whole system (global) or a specific partition.
The following describe how to program the phone option settings that appear under
GLOBAL.
Phone Test (02000)
Phone Options-Global (Default = on)
This setting determines if the user can, at any time, test the communica-
tion from the panel to the central station or a pager by entering
8 +
CODE + 2 (# + 8 + CODE + 2 from a touch-tone phone).
Note
For UL 1610 & 1635 listed installations, this feature must be set to on.
¾To turn the Phone Test setting off or on:
1. With the display showing PHONE TEST OFF/ON
(current setting), press 1 (off) or 2 (on). The
display flashes the entered setting.
2. Press # and the display shows the new setting.
Auto Phone Test (02001)
Phone Options-Global (Default = off)
This setting determines if the panel sends a phone test automatically to the
central station or a pager on a predetermined schedule. (Refer to the
“Phone Test Freq.” and “Next Phone Test” settings found under
TIMERS—
GLOBAL
).
Note
For UL 1610 & 1635 listed installations, this feature must be set to on.
¾To turn Automatic Phone Test off or on:
1. With the display showing AUTO PHONE TEST
OFF/ON
(current setting), press 1 (off) or 2
(on). The display flashes the entered setting.
2. Press # and the display shows the new set-
ting.
Auto Test Reset (02002)
Phone Options-Global (Default = on)
This setting determines whether or not the Auto Phone Test interval is reset after any
successful report to the central monitoring station. (Refer to the “Phone Test Freq.”
and “Next Phone Test” settings found under
TIMERS—GLOBAL).
When this feature is on, the panel considers any successful report to the central mon-
itoring station to be a successful phone test. Thus, any panel report resets the Next
Phone Test setting to the Phone Test Freq. value. The panel only conducts an Auto
Phone Test if no other reports have been made during the Phone Test Freq. time
period.
Note
Phone Test Freq must be set to 2 or higher for Auto Test Reset to work.
When this feature is off, an Auto Phone Test is always conducted according to the
schedule of the Phone Test Freq. setting, even if the panel makes other reports to the
central monitoring station during that time period.
¾
To turn Auto Test Reset off or on:
1. With the display showing AUTO TEST
RESET OFF/ON
(current setting),
press
1 (off) or 2 (on). The display
flashes the entered setting.
2. Press # and the display shows the new
setting.
Comm Failure (02003)
Phone Options-Global (Default = on)
This setting determines whether the panel activates trouble beeps to alert users on
the premises that communication to the central station failed. Failure notification
occurs after the third unsuccessful reporting attempt to the central station/pager.
If a Phone Supervision Card (60-789) is installed, failure notification can occur
immediately if inadequate phone line voltage is detected upon the initial dialing
attempt.
Note
For UL Listed installations, Comm Failure must be turned on.
¾To turn Communication Failure notifi-
cation off or on:
1. With the display showing COMM
FAILURE OFF/ON (current setting),
press 1 (off) or 2 (on). The display
flashes the entered setting.
2. Press # and the display shows the
new setting.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Interlogix Concord Security System and is the answer not in the manual?

GE Interlogix Concord Security System Specifications

General IconGeneral
BrandGE Interlogix
ModelConcord Security System
CategorySecurity System
LanguageEnglish

Related product manuals