Concord 34
The following describes how to program the phone settings that appear under DOWNLOADER
PHONE.
Open/Close Rpts (pager 1: 0134, pager 2: 0144, pager 3:
0154, pager 4: 0164, pager 5: 0174)
Phones-Pager Phone 1-5 (Default = off)
This setting determines whether opening and closing reports are sent to a
pager. When turned on, the panel sends a closing report when the system
is armed and an opening report when the system is disarmed.
Note
To use this feature, the opening reports and closing reports settings under the
REPORTING menu must be turned on for that partition.
¾To turn Opening/Closing Reports off or on:
1. With the display showing OPEN/CLOSE RPTS
OFF/ON
(current setting), press 1 (off) or 2
(on). The display flashes the entered setting.
2. Press # and the display shows the new setting.
Latchkey Reports (pager 1: 0135, pager 2: 0145, pager
3: 0155, pager 4: 0165, pager 5: 0175)
Phones-Pager Phone 1-5 (Default = on)
This setting determines whether the panel reports to a pager when the
system is armed or disarmed, according to latchkey time scheduling.
¾
To turn Latchkey reports off or on:
1. With the display showing LATCHKEY RPTS
OFF/ON
(current setting), press 1 (off) or 2
(on). The display flashes the entered setting.
2. Press # and the display shows the new setting.
Streamlining (pager 1: 0136, pager 2: 0146, pager 3:
0156, pager 4: 0166, pager 5: 0176)
Phones-Pager Phone 1-5 (Default = on)
This setting determines whether the panel includes (off) or excludes
(on) the account number when reporting to a pager.
¾
To turn Streamlining off or on:
1. With the display showing STREAMLINING OFF/
ON
(current setting), press 1 (off) or 2 (on). The
display flashes the entered setting.
2. Press # and the display shows the new setting.
Ptn Assignment (pager 1: 0137, pager 2: 0147, pager 3:
0157, pager 4: 0167, pager 5: 0177)
Phones-Pager Phone 1-5 (Default = 1)
This setting determines the partition that reports to a pager. Both parti-
tions can be assigned to report to a single pager.
¾
To set up Partition Assignments for pager
reporting:
1. With the display showing PTN ASSIGNMENT 1/2/
12
(current setting), press 1 or 2 to select parti-
tion 1 or 2 (press 1 and 2 to select both parti-
tion 1 and 2). The display flashes the entered
setting.
2. Press # and the display shows the new setting.
Phone Number (0180)
Phones-Downloader Phone (Default = none)
Use this setting to enter the phone number of an off-site computer that
can be used to program the panel through the phone line. Phone numbers
can be 1 to 24 digits long, including pauses or * and # characters.
Note
Call-waiting services should be disabled to prevent interrupting panel commu-
nication to the downloader. To program a dialing prefix that disables call-wait-
ing, see the Call Wait Cancel setting under the menu
PHONE OPTIONS—
GLOBAL
.
To enter pauses, press C.
To enter *, press and hold 7 for about two seconds.
To enter #, press and hold 9 for about two seconds.
¾
To program a downloader phone number:
1. With the display showing PHONE NUMBER (cur-
rent number), enter the desired phone number.
The display flashes the entered number.
2. Press # and the display shows the new setting.
¾
To delete a downloader phone number:
1. With the display showing PHONE NUMBER (cur-
rent number), press D to erase the number. The
display shows
PHONE NUMBER_.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Interlogix Concord Security System and is the answer not in the manual?

GE Interlogix Concord Security System Specifications

General IconGeneral
BrandGE Interlogix
ModelConcord Security System
CategorySecurity System
LanguageEnglish

Related product manuals