Concord
55
The following describes how to program the settings that appear under SNAPCARDS.
Key Beeps
Acc. Modules-Bus Devices-Unit ID-Keypad Options
(Default = on)
This setting determines whether or not selected touchpads
beep when their buttons are pressed.
This feature is usually turned off for a touchpad that is
located in or near bedrooms, to avoid disturbing sleeping per-
sons.
¾
To turn Key Beeps on or off:
1. With the display showing the desired touchpad, press #
then A or B until the display shows
KEYPAD OPTIONS.
Next, press # then A or B until the display shows
KEY
BEEPS OFF/ON
(current setting).
2. Press 1 (off) or 2 (on) to select the desired setting. The dis-
play flashes the entered selection. Press # and the display
shows the new setting.
Freeze Temp
Acc. Modules-Bus Devices-Unit ID-Energy Options
(Default = 42°F)
This setting determines the temperature point that the Energy
Saver Module detects a potential freeze (heating failure) con-
dition. The adjustable range is from 40° to 90°F.
¾
To change the Freeze Temp setting:
1. With the display showing the desired bus device press #,
then A or B until the display shows
ENERGY OPTIONS.
Next, press # then A or B until the display shows
FREEZE
TEMP nn DEGREES
(current setting).
2. Enter the desired freeze temperature (40°–90° F). The dis-
play flashes the entered selection. Press # and the display
shows the new setting.
Temperature
Acc. Modules-Bus Devices-Unit ID-Energy Options
(Default = none)
This setting lets you adjust the Energy Saver Module (ESM)
room temperature setting to match the premises thermostat.
The adjustable range is from 40°–90°F.
Note
To ensure accuracy, wait at least 15 minutes before setting the
ESM temperature to allow the ESM to warm or cool to actual
room temperature.
¾To change the ESM Temperature setting:
1. With the display showing the desired bus device press #,
then A or B until the display shows ENERGY OPTIONS.
Next, press # and then A or B until the display shows
TEM-
PERATURE nn DEGREES
(current setting).
2. Enter the desired temperature (40°–90° F). The display
flashes the entered selection. Press # and the display shows
the new setting.
Cellular System
Acc. Modules-Bus Devices-Unit ID-Cellular Options
(Default = B)
This setting determines the cellular transmission system (A
or B) used for cellular communication. This information is
provided by the cellular provider based on installation ZIP
code.
¾
To set the Cellular System:
1. With the display showing the desired bus device press 1,
(B) or 2 (A). The display flashes the entered selection.
2. Press # and the display shows the new setting.