EasyManua.ls Logo

GE Interlogix Concord Security System - User Manual

GE Interlogix Concord Security System
106 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
)
*(,QWHUORJL[
S t a t u s
F e a t u r e s
p r e s s b o t h
L i g h t s
S y s t e m
A w a y
Q u i c k E x i t
O f f
N o D e l a y
p r e s s b o t h
p r e s s b o t h
T e s t S y s t e m W e e k l y
S i l e n t
S t a y
D
*
7
0 #
8
B
A
4
1
5
6
2
3
B y p a s s
M e n u
C
9
P r o g r a m U s e r S e t t i n g s
p r e s s 0 - 9 f o r o t h e r e n t r i e s .
P r e s s 1 f o r O F F ; p r e s s 2 f o r O N ;
P r e s s # t o s e l e c t o p t i o n o r a c c e p t e n t r
y .
0 6
0 7
0 5
0 4
1 3
1 4
1 2
1 1
A r m t o S T A Y
Q u i c k G u i d e
D i s a r m S y s t e m / C a n c e l A l a r m
i f d e s i r e d .
2
0 1
0 2
0 3
3
1
0 8
0 9
1 0
P r e s s t o d e s e l e c t o p t i o n o r c a n c e l e n t r y .
C l o s e a l l p r o t e c t e d d o o r s a n d w i n d o w s .
P r e s s 3 + C O D E .
E x i t p r e m i s e s t h r o u g h d e l a y d o o r .
2
3
1
P r e s s 2 + C O D E .
C l o s e a l l p r o t e c t e d d o o r s a n d w i n d o w s .
P r e s s 4 t o a r m d e l a y d o o r s i n s t a n t l y ,
A r m t o A W A Y
Z o n e / S e n s o r N u m b e r
P r e s s 1 + C O D E .
2
1
P r e s s A o r B t o s c r o l l t h r o u g h m e n u s .
M a k e s u r e s y s t e m i s d i s a r m e d .
2
1
P r e s s 7 + 1 t o t u r n C H I M E o n o r o f f .
M a k e s u r e s y s t e m i s d i s a r m e d .
2
1
T u r n C H I M E O n / O f f
P r e s s B Y P A S S + C O D E + S e n s o r N o .
A r m s y s t e m t o d e s i r e d l e v e l .
B y p a s s S e n s o r s
S y s t e m i s O K
S t a t u s
F e a t u r e s
p r e s s b o t h
L i g h t s
S y s t e m
A w a y
Q u i c k E x i t
O f f
N o D e l a y
p r e s s b o t h
p r e s s b o t h
T e s t S y s t e m W e e k l y
S i l e n t
S t a y
D
*
7
0 #
8
B
A
4
1
5
6
2
3
B y p a s s
M e n u
C
9
A r m e d
R e a d y
Installation Instructions
466-1512-01 Rev F
August 2003
Concord Security System
(Software Version 3.1)
Part Numbers:
60-792-01-95R
60-734-01
60-801-01
ZZZ*(,QWHUORJL[FRP

Table of Contents

Questions and Answers

  • Z
    zachary64Sep 9, 2025
    What to do if installer cannot remember GE Interlogix Concord Security System dealer code?
    • A
      Arthur BradleySep 9, 2025
      If the installer can't remember the dealer code for the GE Interlogix Security System, check your records to see if you have the dealer code on file.
  • A
    alison74Aug 23, 2025
    How to troubleshoot GE Interlogix Concord when the panel does not power up?
    • C
      Christina LopezAug 23, 2025
      If your GE Interlogix Security System panel isn't powering up and the touchpads aren't displaying or responding, try the following: 1. Ensure the panel transformer is plugged into an unswitched outlet. 2. Check the AC circuit breaker to confirm the circuit is live. 3. Verify the backup battery is correctly installed and the AC power transformer is plugged in. 4. Check the panel and transformer wiring for any issues. 5. Measure the incoming AC voltage at panel terminals 1 and 2; it should be approximately 24 VAC.
  • C
    Connor RichardsonAug 25, 2025
    What to do if I forgot my GE Interlogix Concord access code?
    • C
      Connie WhiteAug 25, 2025
      If you've forgotten your access code for the GE Interlogix Security System, here's what you can do: First, check your personal records to see if you have the access code on file. You can also verify the access code using the Downloader. If all else fails, clear the memory and reprogram the panel locally.
  • M
    matthew67Aug 26, 2025
    What to do if my GE Interlogix Concord Security System won’t disarm?
    • B
      Brian CarterAug 26, 2025
      If your GE Interlogix Security System won't disarm, consider these possibilities: You might be entering the incorrect code, so make sure you're using the right one. It's also possible that the access code you're using isn't programmed or set up in the user programming to disarm the system.
  • T
    Timothy CarlsonAug 27, 2025
    What to do if installer cannot remember GE Interlogix Security System install code?
    • H
      hansonjulieAug 28, 2025
      If the installer can't remember the install code for the GE Interlogix Security System: First, check your records to see if you have the install code on file. You can also verify the install code using the Downloader. Alternatively, use the Dealer Code to enter program mode and view the installer code.
  • M
    mikereedAug 29, 2025
    Why does my GE Interlogix Security System protest and won’t arm?
    • B
      bryan59Aug 29, 2025
      If your GE Interlogix Security System protests and won’t arm, consider the following: If you are arming to level 2, ensure all monitored perimeter doors and windows are closed. If arming to level 3, ensure all perimeter and interior sensors are closed.
  • A
    ashleyjohnsonSep 18, 2025
    Why doesn't the module temperature match actual room temperature on my GE Interlogix Security System?
    • V
      Victoria MillsSep 18, 2025
      If the module temperature does not match the actual room temperature on your GE Interlogix Security System, it's possible that the module room temperature setting has not been adjusted or was adjusted before the module warmed or cooled to room temperature.
  • D
    Dana HamiltonSep 18, 2025
    Why doesn’t cellular backup report occur on my GE Interlogix Security System?
    • R
      Ryan KempSep 19, 2025
      If the cellular backup report does not occur on your GE Interlogix Security System, verify the Cellular Backup option is on for the CS phone number being tested.
  • A
    Amanda HarperSep 7, 2025
    Why don't my GE Interlogix Concord Security System touchpad buttons beep when pressed?
    • M
      Meghan ParsonsSep 7, 2025
      If the touchpad buttons on your GE Interlogix Security System don't beep when pressed: First, check for touchpad power issues or bus miswiring, opens, or shorts. Second, verify that the key beeps option is enabled.
  • V
    vanessa03Sep 4, 2025
    Why does my GE Interlogix Concord Security System display show all asterisks?
    • J
      Joshua FarmerSep 5, 2025
      If your GE Interlogix Security System display shows all asterisks, it indicates that the touchpad is either not connected to the panel bus terminals or is wired incorrectly. Check and correct the wiring.

Summary

About This Manual

Special Installation Requirements

Requirements dictated by codes, insurance, or Underwriter's Laboratories (UL).

UL Listed Installations

Describes the requirements for UL Listed installations.

Planning the Installation

Standard Panel

Describes the basic panel hardware capabilities out-of-box.

Installing the System

Determine the Panel Location

Guidelines for selecting the central panel location.

Mounting the Panel

Procedure for mounting the panel to a wall or wall studs.

Identify Panel Components

Connecting Panel to Earth Ground and Installing Cards

Grounding the panel and installing Power Line Carrier/Phone Supervision cards.

Installing Optional SnapCards

Allows installation of one SnapCard to expand panel functionality.

Connecting Detection Devices

Intrusion Detection Devices

Typical wiring for N/C and N/O door/window intrusion detection and motion detectors.

Smoke Detectors

Details for connecting 2-wire and 4-wire smoke detectors to zone input 8.

Connecting Audio and Siren Devices

Speakers and Sirens

Connecting speakers, piezo sirens, and supervised wireless sirens to the panel.

Installing Modules and Peripherals

SuperBus 2000 Modules

Installing RF Receiver, Phone Interface/Voice Module, and other SuperBus modules.

RJ-31 X Phone Jack and Wiring

Guidelines for installing an RJ-31X phone jack and connecting the phone line.

Powering Up and Initial Setup

Connecting AC Power Transformer and Powering Up Panel

Connects the transformer and applies AC/battery power to the panel.

Programming the Panel

Entering Program Mode

Procedures to enter the system's installer/dealer programming mode.

Programming Tier 1 Menu Items

Guides through the first tier of system programming menus.

System Settings and Options

Installer Code and Downloader Code

Setting essential codes for system access and programming.

Phone and Reporting Settings

Configuring central station reporting, phone numbers, and report formats.

Timers and Schedules

Timers Menu

Setting time-based features like RF Tx Timeout and Phone Test Frequency.

Set Up Schedules Menu

Sets time frames for light control and opening/closing reports.

Testing the System

Testing Zones;Sensors

Tests sensors and zones after installation or programming changes.

Testing Phone Communication

Checks panel communication with central station/pager.

Troubleshooting

Panel Power Issues

Troubleshoots problems related to the panel not powering up.

Wireless Sensor Issues

Troubleshoots wireless sensor response or trouble conditions.

Appendices

Table A1: Wireless Devices

Lists part numbers and descriptions for wireless devices.

Table B1: Sensor Group Characteristics

Details characteristics of different sensor groups.

GE Interlogix Concord Security System Specifications

General IconGeneral
BrandGE Interlogix
ModelConcord Security System
CategorySecurity System
LanguageEnglish

Related product manuals