Concord 68
Testing Central Station/Pager Communication
After performing sensor and phone tests, check that the system is reporting alarms successfully
to the central station or pager.
Be sure to contact the central monitoring station before activating outputs that trigger
from an alarm condition.
Note
The way information is dis-
played varies with pager ser-
vices and may not match the
example above. Account
numbers with alpha-charac-
ters also vary when dis-
played, depending on pager
service. Account numbers
are not displayed if
STREAMLINING is turned
on.
¾To test communication with the central station/pager:
1. Call the central station and tell the operator that you will be testing the system.
2. Arm the system.
3. Test each of the touchpad and wireless panic buttons and trip at least one sensor of each type
(fire, intrusion, etc.) to verify correct operation.
4. Check pager displays to verify reports are received. Pagers display an event code, digit sen-
sor number, and the last four digits of the account number. For example, a pager display of
999 002 7468 indicates the following:
999 = alarm condition,
002 = sensor/zone in alarm or user number,
7468 = last four digits of account number.
5. When you finish testing the system, call the central monitoring station to verify that the
alarms were received.
Table 10 describes pager system event codes.
Table 11 describes pager sensor/zone number and user number report codes.
Testing Outputs and Sirens
All outputs (onboard and SnapCard) should be tested to verify configuration programming.
Caution
!
Table 10: Pager System Event Codes
Code System Event
009 Zone Restoral
111 System Disarmed
115 Sensor Test Exit
118 Trouble condition cleared
119 Alarm Canceled
222 System Armed to STAY
333 System Armed to AWAY
555 Phone/Sensor Test
888 System Trouble Condition
999 System in Alarm
Table 11: Pager Sensor/Zone Code and Numbers
Code Sensor/Zone or User Number
000 System event not caused by a zone or user
001–096 Sensor/Zone Numbers 1–96
600–829 Regular User Codes 0–229 used
846 System Master Code used
847 Installer Code used
848 Dealer Code used
850 Quick Arm used
851 Keyswitch Sensor used
852 System Armed Itself (during service or power-up)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Interlogix Concord Security System and is the answer not in the manual?

GE Interlogix Concord Security System Specifications

General IconGeneral
BrandGE Interlogix
ModelConcord Security System
CategorySecurity System
LanguageEnglish

Related product manuals