Concord
31
Phone Number (cs phone 1: 0100, cs phone 2: 0110,
cs phone 3: 0120)
Phones-CS 1-3 (Default = none)
This setting is used for programming the central station receiver phone number.
Phone numbers can be 1 to 24 digits long, including pauses or * and # characters.
To enter pauses, press C.
To enter *, press and hold 7 for about two seconds.
To enter #, press and hold 9 for about two seconds.
Note
The
PHONE NUMBER menus are not accessible if a Dealer Code is programmed and the
Installer Code is used to enter installer programming mode. To access these menus
when a Dealer Code is programmed, you must enter installer programming mode using
the Dealer Code.
Call-waiting services should be disabled to prevent interrupting panel communication to
the central monitoring station. To program a dialing prefix that disables call-waiting, see
the Call Wait Cancel setting under the menu
PHONE OPTIONS—GLOBAL.
For UL 1610 & 1635 installations, a phone number must be programmed.
¾To program a Central Station Phone
Number:
1. With the display showing PHONE
NUMBER _
(or current number), enter
the desired phone number. The display
flashes the entered number.
2. Press # and the display shows the new
number.
¾
To delete a Central Station Phone
Number:
With the display showing PHONE
NUMBER
(current number), press D.
The display shows PHONE NUMBER _.
High Level Rpts (cs phone 1: 0101, cs phone 2: 0111,
cs phone 3: 0121)
Phones-CS 1-3 (Defaults:1 = on, 2&3 = off)
When this setting is on, the following conditions report to the central sta-
tion:
Fire, Police, Auxiliary, and Duress alarms
•No Activity
Receiver Failure (or jam)
Tamper conditions, including Zone Tampers and System Tamper (40
incorrect key presses or touchpad supervisory)
Entering or exiting Sensor Test mode
Phone Test
Note
For UL 1610 & 1635 installations, this feature must be set to on.
¾To turn High-Level Reports off or on:
1. With the display showing HIGH LEVEL RPTS
OFF/ON
(current setting), press 1 (off) or 2
(on). The display flashes the entered setting.
2. Press # and the display shows the new set-
ting.
Low Level Rpts (cs phone 1: 0102, cs phone 2: 0112,
cs phone 3: 0122)
Phones-CS 1-3 (Defaults:1 = on, 2&3 = off)
When this setting is on, the following non-alarm conditions report to the
central station:
Force Armed
Hardwire Zone Trouble (open or short)
Supervisory (wireless devices)
Low Battery (wireless devices)
Phone Test
Other non-alarm related conditions
Note
For UL 1610 & 1635 installations, this feature must be set to on.
¾To turn Low-Level Reports off or on:
1. With the display showing LOW LEVEL RPTS
OFF/ON (current setting), press 1 (off) or 2
(on). The display flashes the entered setting.
2. Press # and the display shows the new set-
ting.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Interlogix Concord Security System and is the answer not in the manual?

GE Interlogix Concord Security System Specifications

General IconGeneral
BrandGE Interlogix
ModelConcord Security System
CategorySecurity System
LanguageEnglish

Related product manuals