Concord
31
Phone Number (cs phone 1: 0100, cs phone 2: 0110,
cs phone 3: 0120)
Phones-CS 1-3 (Default = none)
This setting is used for programming the central station receiver phone number.
Phone numbers can be 1 to 24 digits long, including pauses or * and # characters.
To enter pauses, press C.
To enter *, press and hold 7 for about two seconds.
To enter #, press and hold 9 for about two seconds.
Note
The
PHONE NUMBER menus are not accessible if a Dealer Code is programmed and the
Installer Code is used to enter installer programming mode. To access these menus
when a Dealer Code is programmed, you must enter installer programming mode using
the Dealer Code.
Call-waiting services should be disabled to prevent interrupting panel communication to
the central monitoring station. To program a dialing prefix that disables call-waiting, see
the Call Wait Cancel setting under the menu
PHONE OPTIONS—GLOBAL.
For UL 1610 & 1635 installations, a phone number must be programmed.
¾To program a Central Station Phone
Number:
1. With the display showing PHONE
NUMBER _
(or current number), enter
the desired phone number. The display
flashes the entered number.
2. Press # and the display shows the new
number.
¾
To delete a Central Station Phone
Number:
With the display showing PHONE
NUMBER
(current number), press D.
The display shows PHONE NUMBER _.
High Level Rpts (cs phone 1: 0101, cs phone 2: 0111,
cs phone 3: 0121)
Phones-CS 1-3 (Defaults:1 = on, 2&3 = off)
When this setting is on, the following conditions report to the central sta-
tion:
• Fire, Police, Auxiliary, and Duress alarms
•No Activity
• Receiver Failure (or jam)
• Tamper conditions, including Zone Tampers and System Tamper (40
incorrect key presses or touchpad supervisory)
• Entering or exiting Sensor Test mode
• Phone Test
Note
For UL 1610 & 1635 installations, this feature must be set to on.
¾To turn High-Level Reports off or on:
1. With the display showing HIGH LEVEL RPTS
OFF/ON
(current setting), press 1 (off) or 2
(on). The display flashes the entered setting.
2. Press # and the display shows the new set-
ting.
Low Level Rpts (cs phone 1: 0102, cs phone 2: 0112,
cs phone 3: 0122)
Phones-CS 1-3 (Defaults:1 = on, 2&3 = off)
When this setting is on, the following non-alarm conditions report to the
central station:
• Force Armed
• Hardwire Zone Trouble (open or short)
• Supervisory (wireless devices)
• Low Battery (wireless devices)
• Phone Test
• Other non-alarm related conditions
Note
For UL 1610 & 1635 installations, this feature must be set to on.
¾To turn Low-Level Reports off or on:
1. With the display showing LOW LEVEL RPTS
OFF/ON (current setting), press 1 (off) or 2
(on). The display flashes the entered setting.
2. Press # and the display shows the new set-
ting.