EasyManuals Logo

GE Interlogix Concord Security System User Manual

GE Interlogix Concord Security System
106 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #37 background imageLoading...
Page #37 background image
Concord 32
The following describes how to program the phone settings that appear under PAGER PHONE 1-5.
Exception Rpts (cs phone 1: 0103, cs phone 2: 0113,
cs phone 3: 0123)
Phones-CS 1-3 (Default = off)
When this setting is on, the panel reports to the central station if the sys-
tem is not armed or disarmed at the specified schedule times.
¾
To turn Exception Reports off or on:
1. With the display showing EXCEPTION RPTS
OFF/ON
(current setting), press 1 (off) or 2
(on). The display flashes the entered setting.
2. Press # and the display shows the new setting.
Open/Close Rpts (cs phone 1: 0104, cs phone 2: 0114,
cs phone 3: 0124)
Phones-CS 1-3 (Default = off)
This setting determines whether opening and closing reports are sent to
the central station. When turned on, the panel sends a closing report when
the system is armed and an opening report when the system is disarmed.
Note
To use this feature, the Opening Reports and Closing Reports settings under
the
REPORTING menu must be turned on for that partition.
¾To turn Opening/Closing Reports off or on:
1. With the display showing OPEN/CLOSE RPTS
OFF/ON (current setting), press 1 (off) or 2
(on). The display flashes the entered setting.
2. Press # and the display shows the new set-
ting.
Backup (cs phone 1: 0105, cs phone 2: 0115,
cs phone 3: 0125)
Phones-CS 1-3 (Defaults:1 = on, 2&3 = off)
This setting determines whether or not the panel uses another programmed
central station phone number for reporting if attempts with the first num-
ber are unsuccessful.
When Back Up is off, the panel will make up to eight attempts to deliver a
report with the programmed phone number.
When Back Up is set to on, the panel makes up to 16 attempts to deliver
the report, alternating between the programmed phone number and the
backup phone number.
CS PHONE 1 is backed up by CS PHONE 2.
CS PHONE 2 is backed up by CS PHONE 1.
CS PHONE 3 is backed up by CS PHONE 1.
¾
To turn Backup off or on:
1. With the display showing BACK UP OFF/ON
(current setting), press 1 (off) or 2 (on). The
display flashes the entered setting.
2. Press # and the display shows the new set-
ting.
SIA/CID Reporting (cs phone 1: 0106, cs phone 2: 0116,
cs phone 3: 0126)
Phones-CS 1-3 (Default = CID)
This setting determines whether the panel uses the SIA or CID (Contact
ID) reporting format for central station communication.
¾
To select SIA or CID reporting:
1. With the display showing REPORTING FORMAT
SIA/CID
(current setting), press 1 (for SIA) or 2
(for CID). The display flashes the entered set-
ting.
2. Press # and the display shows the new setting.
Cellular Backup (cs phone 1: 0107, cs phone 2: 0117,
cs phone 3: 0127)
Phones-CS 1-3 (Defaults:1 = on, 2&3 = off)
This setting determines whether the panel uses cellular communication
for reporting if attempts using a landline are unsuccessful.
¾
To turn Cellular Backup off or on:
1. With the display showing CELLULAR BACKUP,
press 1 (off) or 2 (on). The display flashes the
entered setting.
2. Press # and the display shows the new setting.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Interlogix Concord Security System and is the answer not in the manual?

GE Interlogix Concord Security System Specifications

General IconGeneral
BrandGE Interlogix
ModelConcord Security System
CategorySecurity System
LanguageEnglish

Related product manuals