Concord 40
The following sections describe the timer settings that appear under PARTITION 1-2.
Next Phone Test (0303)
Timers-Global (Default = 7 days)
This setting is used by the Auto Phone Test feature (see
PHONE OPTIONS—
GLOBAL
) to determine when the next automatic phone test should occur.
This setting should be the same as, or less than, the Phone Test Freq. set-
ting.
Note
For UL 1610 & 1635 listed installations, this feature must be set to 1.
¾To set the Next Phone Test:
1. With the display showing NEXT PHONE TEST
nnn DAYS (current setting), enter the number of
days (1–255). The display flashes the entered
setting.
2. Press # and the display shows the new setting.
Output Trip Time (0304)
Timers-Global (Default = 4 sec.)
This setting determines how long outputs are activated
when tripped (if they are configured for a momentary
response).
¾
To set the Output Trip Time:
1. With the display showing OUTPUT TRIP TIME nn SECS (current
setting), enter the number of seconds (1–12). The display
flashes the entered setting.
2. Press # and the display shows the new setting.
Activity Timeout (0305)
Timers-Global (Default = 24 hours)
This setting determines when the system sends a “no activity” report.
The panel can be set to wait from 1–42 hours. If no user interaction or
device activation occurs in that time, the panel sends a report to the cen-
tral station.
¾
To set the Activity Timeout:
1. With the display showing ACTIVITY TIMEOUT
nn HOURS
(current setting), enter the number
of hours (1–42). The display flashes the
entered setting.
2. Press # and the display shows the new setting.
Daylight Saving (0306)
Timers-Global (Default = on)
When this setting is on, the panel clock automatically adjusts for daylight
saving time changes.
¾
To turn Daylight Saving off or on:
1. With the display showing DAYLIGHT SAVING
OFF/ON
(current setting), press 1 (off) or 2
(on). The display flashes the entered setting.
2. Press # and the display shows the new setting.
Entry Delay (partition 1: 0310, partition 2: 0320)
Timers-Partition 1-2 (Default = 30 sec.)
This setting determines how much time the user has to disarm the system
(after entering the armed premises through a “designated delay door”)
without causing an alarm.
Note
For UL 1023 Listed installations, the Entry Delay must be set to 45 seconds or
less. The combined time for the Entry Delay and Dialer Abort Delay (02006)
must not exceed 60 seconds.
¾To set the Entry Delay:
1. With the display showing ENTRY DELAY nnn
SECS
(current setting), enter the desired time
value (30–240 using 8-second intervals). The
display flashes the entered setting.
2. Press # and the display shows the new setting.
Exit Delay (partition 1: 0311, partition 2: 0321)
Timers-Partition 1-2 (Default = 60 sec.)
This setting determines how much time the user has (after arming the sys-
tem) to leave the premises through a “designated delay door” without
causing an alarm.
Note
For UL 1023 listed installations, this feature must be set to 60 seconds or less.
For UL 1610 listed installations, this feature must be set to 120 seconds or less.
¾To set the Exit Delay:
1. With the display showing EXIT DELAY nnn
SECS
(current setting), enter the desired time
value (45–184 using 8-second intervals). The
display flashes the entered setting.
2. Press # and the display shows the new setting.