Concord
91
Notes for Table B7: Response Numbers
Note
The mechanical lifetime of
the relay may be exceeded if
an output is set up for a siren
tracking response and a
pulsing siren (auxiliary or
fire) is active for long time
periods. A SnapCard relay
output’s lifetime expectancy
is about 350 total pulsing
hours.
1. If an event does not trigger sirens, siren tracking response numbers activate without turning
on the output. If sirens are triggered by another event, the output pulses to match the siren.
If the siren cadence changes (from police to fire, for example), outputs set up for siren track-
ing change to match the siren and all pulsing outputs pulse to one common cadence.
2. If an event does not trigger sirens, siren time response times activate outputs only if sirens
are active for another reason.
3. If an alarm event does not necessarily require disarming (no activity, closing report, etc.),
outputs set up for a sustained response time remain activated until the next arming level
change.
4. If an event occurs that activates an output set up for trip delay, the delay and output activa-
tion can be canceled by trigger event restoral.
Note
The trip delay is factory set
for 30 seconds and cannot
be changed.
5. Activated outputs set up for a 3-minute response time remain active for the entire three min-
utes. To deactivate the output before the 3-minute time expires, you must enter program
mode or remove panel power.
Activated outputs set up for a momentary or 3-minute response time restart if the same trig-
ger event occurs again.
Table B7: Response Numbers
Siren
Tracking
Trip Delay
Response
Time
Response
No.
no no momentary 00
no no
3 minutes
5
01
no no
siren time
2
02
no no
sustained
3
03
no
yes
4
momentary 04
no
yes
4
3 minutes
5
05
no
yes
4
siren time
2
06
no
yes
4
sustained
3
07
yes
1
no momentary 08
yes
1
no
3 minutes
5
09
yes
1
no
siren time
2
10
yes
1
no
sustained
3
11
yes
1
yes
4
momentary 12
yes
1
yes
4
3 minutes
5
13
yes
1
yes
4
siren time
2
14
yes
1
yes
4
sustained
3
15

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Interlogix Concord Security System and is the answer not in the manual?

GE Interlogix Concord Security System Specifications

General IconGeneral
BrandGE Interlogix
ModelConcord Security System
CategorySecurity System
LanguageEnglish

Related product manuals