EasyManuals Logo

GE Security Simon XT Installation Manual

GE Security Simon XT
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #18 background imageLoading...
Page #18 background image
Simon XT
Installation Manual
8
15 Instant interior: Interior PIR motion sensors. Intrusion F Y Y 234
16 Instant interior: Interior doors. Intrusion F Y Y 34
17
Instant interior: PIR motion sensors and Sound sensors.
Intrusion F N Y 34
18 Instant interior: Cross-zone PIR motion sensors. Intrusion F N Y 34
19 Delayed interior: Interior doors that initiate a delay before going into alarm. Intrusion S Y Y 34
20 Delayed interior: PIR motion sensors that initiate a delay before going into
alarm.
Intrusion S N Y 34
21 Local instant interior: 24-hour local alarm zone protecting anything that opens
and closes. No report.
Intrusion I Y Y 1234
22 Local delayed interior: same as group 21, plus activation initiates a delay
before going into alarm. No report.
Intrusion S Y Y 1234
23 Local instant auxiliary: 24-hour local alarm zone protecting anything that
opens and closes. No report.
Emergency I Y Y 01234
24 Local instant auxiliary: 24-hour local alarm zone protecting anything that
opens and closes. Sirens shut off at restoral. No report.
Emergency I Y Y 01234
25 Local special chime: notify the user when a door is opened. Sounds emit from a
local annunciator. One direct bypass and unbypass when no special motion
chime sensors are in the security system. No report.
Three beeps I N Y 01234
26 Fire: 24-hour fire, rate-of-rise heat, and smoke sensors. Fire I Y Y 01234
27 Lamp control or other customer feature. No report. Silent I Y Y 01234
28
PIR motion sensor, sound sensor, or pressure mat.
RF thermostat. No report.
Silent I N Y 01234
29 Auxiliary: freeze sensors. Trouble beeps I Y Y 01234
32 PIR motion sensor or sound sensor. No report. Silent I N N 01234
34 Carbon monoxide alarm. Emergency I Y Y 01234
35 Entry/exit delay interior PIR motion. Intrusion S N Y 234
36 Special Intrusion: such as gun cabinets and wall safes. Reports as tamper if
tripped.
Intrusion I Y Y 1234
37 Light switch control: X10 modules turn either on or off when a door is opened. Silent I N Y 01234
38 Auxiliary: water sensors. Trouble beeps I Y Y 01234
39 Local instant interior: 24-hour local alarm zone protecting anything that opens
and closes. No report.
Intrusion I Y Y 1234
40 Local special chime. Three beeps I Y Y 01234
Table 4. Sensor group characteristics (continued)
Type
Name/application Siren type
Delay
Restoral
Supervisory
Active In
arming
levels

Table of Contents

Other manuals for GE Security Simon XT

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Security Simon XT and is the answer not in the manual?

GE Security Simon XT Specifications

General IconGeneral
BrandGE Security
ModelSimon XT
CategorySecurity System
LanguageEnglish

Related product manuals