Function Default Description
Account number 00000 Lets you program up to a 10-character alphanumeric account number or delete an
existing account number by pressing DISARM. You can enter numerical digits
sequentially. To enter letters (A to F only), use the scroll buttons to select A to F then
press Enter. To select next digit, press another number key. When finished press Enter.
The CID format only supports account numbers with letters B through F, or numbers 0
through 9 (or a combination of those letters and numbers).
Downloader
code
12345 Lets you set a unique five-digit code that is required for initiating Enterprise Downloader
sessions. The code must be five digits long and can range from 00000 to 99999. The
downloader code must match the downloader access code in the Enterprise account to
perform Enterprise sessions.
Phone lock Off Prevents resetting of phone/reporting related options when a memory clear is
performed (on) or resets these options to their default values when a memory clear is
performed (off).
The following are not reset when on:
•Account number
•Dealer code
•Code length
•Call wait cancel
• Phone numbers 1 and 2
• Phone report modes 1 to 4
• Phone lock
• Downloader phone number
• Downloader code
Autoarm On Determines how long the system protests (announces open/failed sensors) when
attempting to arm with open/failed sensors, before bypassing these sensors and
automatically arming the rest of the system.
Note: The panel protests an arming attempt when it has not received a restore (close)
signal from sensors learned into restore-specific sensors groups. Sensors
learned into group 26 (fire) cannot be bypassed.
When this option is on, the panel announces all open/failed sensors repeatedly for 4
minutes, then automatically bypasses the open sensors and arms the rest of the
system. If a sensor is opened during the exit delay and then left open, the panel will go
into alarm after the exit delay has expired.
This option must be on for Unvacated premises and Exit extension to work correctly.
When this option is off, the panel displays all open/failed sensors once, then
automatically bypasses the open sensors and arms the rest of the system after the exit
delay has expired. If other sensors are opened during the exit delay, they will also be
bypassed if left open.
Note: If group 13 (Instant Perimeter) sensors are opened during the exit delay, the
panel goes into immediate alarm.