Chapter 4
Programming
41
Editing sensors
You can use this feature to change the group or name of a sensor that is already in panel memory. The
procedure is very similar to the procedure used to program sensor information after a sensor is learned in.
Pressing DISARM while editing sensor text deletes all text for that sensor.
Reporting
Table 16 and Table 17 on page 43 provide report option details.
Table 15. Sensors
Function Default Description
Learn sensors Adds (learns) sensors to panel memory.
Delete sensors Deletes sensors from panel memory.
Edit sensors Edits sensor information in panel memory.
Table 16. Reporting options
Function Default Description
Opening reports Off Determines whether the panel sends opening reports to a central station whenever the
system is disarmed (on), or not (off). User number will be reported as zone number.
Keyfobs learned into zone 1 to 40 will report as zone they are learned into.
Dealer code = 44
Installer code = 45
Master code = 46
User code 1 = 47
User code 2 = 48
User code 3 = 49
User code 4 = 50
User code 5 = 51
User code 6 = 52
User code 7 = 53
User code 8 = 54
Duress code = 55