Chapter 2
Planning
7
Table 3. Recommended sensor groups
Device Recommended sensor group
Indoor motion sensor 17 (intrusion), 25 (chime)
Outdoor motion sensor 25 (chime only)
Entry/exit door 10
Interior door 14
Window sensor 13
Smoke Sensor 26
Keyfob 01, 03, 06, 07
ELM keyfob 01, 03, 06, 07
Remote Handheld Touchpad 01, 03, 06, 07
CO Alarm 34
Freeze Sensor 29
Water Sensor 38
Personal Help Button 01, 03
Table 4. Sensor group characteristics
Type
Name/application Siren type
Delay
Restoral
Supervisory
Active In
arming
levels
00 Fixed panic: 24-hour audible fixed emergency button. Intrusion I N Y 1234
01 Portable panic: 24-hour audible portable emergency buttons. Intrusion I N N 1234
02 Fixed panic: 24-hour silent fixed emergency buttons. Status light will not blink. Silent I N Y 01234
03 Portable panic: 24-hour silent portable emergency buttons. Status light will not
blink.
Silent I N N 01234
04 Fixed auxiliary: 24-hour auxiliary sensor. Emergency I N Y 01234
05 Fixed auxiliary: 24-hour emergency button. Siren shut off confirms CS report. Emergency I N Y 01234
06 Portable auxiliary: 24-hour portable auxiliary alert button. Emergency I N N 01234
07 Portable auxiliary: 24-hour portable auxiliary button. Siren shut off confirms CS
report.
Emergency I N N 01234
08 Special intrusion: such as gun cabinets and wall safes. DTM (tamper only). Intrusion I Y Y 1234
09 Special intrusion: such as gun cabinets and wall safes. Intrusion S Y Y 1234
10 Entry/exit delay: A delay that requires a standard delay time. chime. Intrusion S Y Y 24
13 Instant perimeter: Exterior doors and windows. chime. Intrusion I Y Y 24
14 Instant interior: Interior doors. Intrusion F Y Y 234