EasyManuals Logo

GE Security Simon XT Installation Manual

GE Security Simon XT
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #57 background imageLoading...
Page #57 background image
Chapter 4
Programming
47
Siren options
Table 21 provides siren option details.
Table 21. Siren options
Function Default Description
Piezo beeps On This option determines whether the panel piezo produces beeps based on system
activity (on) or is silent (off).
Panel voice On When On, arming level changes will be spoken.
Panel piezo
alarm
On Determines whether the panel piezo emits alarm sounds (on) or not (off).
Trouble beeps On Determines whether the panel, X10, and hardwired interior sirens sound six beeps every
minute when a trouble condition occurs (on) or not (off). The following conditions cause
trouble beeps:
AC power failure (when AC power failure report is on) low CPU battery
Sensor failure (supervisory)
Sensor trouble (low battery, tamper, etc.)
Fail to communicate
Restoration of power
No Activity timer has timed out. Trouble beeps continue for 5 minutes and if the panel
does not see activity, trouble beeps stop and the panel reports the no activity to the
central station.
Trouble beeps can be silenced by arming or disarming the system or by pressing the
STATUS button. Trouble beeps resume 4 hours later if the trouble condition is not cleared.
Voice chime Off Determines whether the panel announces the sensor name.
1 = Sensor name
2 = Loud ding-dong bell
3 = Soft ding-dong bell
Off = No sound
Status beeps vol. 7 Determines the panel piezo volume level for status sounds such as arming, trouble, and
status beeps. Volume range is 1 (lowest) to 10 (highest).
HW siren sup. Off Determines whether the panel monitors hardwired sirens for open conditions (on) or not
(off). If this option is turned on, sirens connected to the panel terminals require an EOL
resistor in the wire circuit. (See Chapter 3 Installing the system on page 17 for siren
wiring.) If this option is turned off, EOL resistors are not required whether sirens are
connected or not.
Speaker volume 8 Sets the volume of voice messages from the panel speaker. Volume range is 1 (lowest) to
8 (highest).
Silent police
panic
Off Determines whether pressing the panel police panic button causes an audible (off) or
silent (on) alarm.
Panel tamper
alarm
Off Determines whether the panel activates a tamper alarm anytime the cover is opened
(On) or only when the system is armed (Off).
Alarm report
verify
Off This option determines whether the panel verifies successful alarm reports to the central
station by displaying Phone comm is OK (On), or not (Off).

Table of Contents

Other manuals for GE Security Simon XT

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Security Simon XT and is the answer not in the manual?

GE Security Simon XT Specifications

General IconGeneral
BrandGE Security
ModelSimon XT
CategorySecurity System
LanguageEnglish

Related product manuals