Chapter 4
Programming
37
Phone numbers
Exit extend On Determines whether the panel restarts the exit delay time if the user enters the armed
premises during the initial exit delay period (on), or not (off). Turning on this feature
allows users to reenter during the exit delay period, without disarming and then
rearming the system. Turning off this feature requires the user to disarm and rearm the
system.
Note: Autoarm must be on for this option to work.
Secure arming Off Determines whether an access code is required when arming the system (on) or not
(off). This option does not affect keyfob arm/disarm operation.
No arm on low
battery
Off Determines whether the system protests arming if a low CPU battery condition exists
(on) or not (off).
Quick exit Off Determines whether pressing DISARM when the system is armed activates the exit
delay time to allow exit and reentry without disarming the system (on) or not (off).
This feature is useful if the user wants to step outside briefly and return, such as to get
the paper. If the system is armed and the user presses DISARM, the panel announces
Exit time is ON and sounds exit delay beeps. This allows a designated entry/exit door to
be open for up to 2 minutes without causing alarm. When the door is closed, the beeps
stop and the door is armed again.
Note:
Downloader
enable
On Enables programming of system options with downloader software.
Sup protest Off Determines whether the panel protests arming if it has not received a supervisory signal
from any sensor 15 minutes before arming (on) or not (off).
Note: This feature must be turned off for US installations, on for European
installations.
Table 12. Phone numbers
Function Default Description
Phone # 1 Blank Lets you program up to a 26-digit central monitoring station receiver/voice event
notification phone number for monitored systems. Phone digits can be 0-9, *, #, or a
pause (P).
To delete the phone number, press DISARM while editing a phone digit. To add a pause
to the phone number press BYPASS. Pressing Enter is required if you enter fewer than 26
digits.
Phone # 2 Blank
Phone # 3 Blank
Phone # 4 Blank
Downloader # Blank Lets you program up to a 26-digit phone number for the Enterprise Downloader.
Table 11. Security (continued)
Function Default Description

Table of Contents

Other manuals for GE Security Simon XT

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Security Simon XT and is the answer not in the manual?

GE Security Simon XT Specifications

General IconGeneral
BrandGE Security
ModelSimon XT
CategorySecurity System
LanguageEnglish

Related product manuals