Simon XT
Installation Manual
46
System options
Table 20 provides system option details.
Table 20. System options
Function Default Description
RF jam detect Off Determines whether the panel checks for and reports RF interference/jam to the central
station (on) or not (off). If this option is on and the panel receives a constant 319.5 MHz
signal, the panel reports the condition to the central station. If this option is off, the panel
does not detect an RF jam.
Demo mode Off Determines whether the panel operates as a demonstration model (on) or a standard
panel (off).
Turning on this feature disables low battery supervision and allows the microphone to
remain on continuously during an AVM session. With option on panel is not testing
battery supervision.
HW 1 function 1 The setting for this option determines how the HW1 I/O output will function.
SIA limits On Determines whether entry, exit, and dialer delay times fall within SIA limits (on) or factory
ranges (off).
Entry Delay 030 to 240 seconds 005 to 240 seconds
Exit Delay 045 to 254 seconds 005 to 254 seconds
Dialer Delay 015 to 045 seconds 005 to 254 seconds
24-hour clock Off Determines whether the panel uses a 24-hour clock (on) or 12-hour clock (off).
Off = No output.
1 = Interior siren output.
2 = Output activated when armed.
3 = Output activated when disarmed.
4 = Fail to communicate output; activates when fail to communicate condition
occurs (Fail to communicate must be on) two.
5 = Alarm output activated when panel is in alarm