Specifications 8-5
September 2004
Transducer
Specifications (cont.)
Clamp-on Transducers Type:
Shear wave or longitudinal wave.
Temperature Range
Standard: -40
o
to 212
o
F (-40
o
to 100
o
C).
Optional (overall range): -328
o
to 500
o
F (-200
o
to 260
o
C).
Frequency:
Standard: 1 MHz.
Optional: 500 MHz, 2 MHz, or 4 MHz.
Mounting:
SS chain or strap, welded or magnetic slide-track mounting
fixtures.
Housing:
Standard: None (splashproof).
Optional: Explosion-proof, Div. 1, Class 1, Group C&D,
INIEX-certified EEx d IIC T6 or weatherproof (NEMA 4, IP65).
Other Options:
Transducers for special applications; fixtures; no organic bonds or
insulators; cooling jackets for high temperatures. Please consult
GE Infrastructure Sensing for details.
Pipe Size and Materials
Wetted Transducers
Materials:
All metals and most plastics. (Consult the factory for concrete,
glass and cement.)
Pipe Sizes:
Inside Diameter: 0.04 to 200 in. (1 mm to 5 m) and larger.
Clamp-on Transducers Materials:
316 SS and most plastics. (Consult the factory for concrete,
composite materials and highly corroded or lined pipes.)
Pipe Sizes:
Outside Diameter: 0.5 to 200 in. (12.7 mm to 5 m) and larger.
Pipe Wall Thickness:
Up to 3 in. (76.2 mm).