September 2004
2-18 Programming Site Data
Entering KV/SS Table - KV/
SS
Use this option to calculate the kinematic viscosity (KV) based on
signal strength (SS). Complete the following steps to enter KV and
SS values:
1. Press [ESC], [ENTER], [ESC]. The meter enters the user program.
2. Press [
X] until PROG appears and press [ENTER].
3. Press [
X] until the desired channel appears. Press [ENTER] at CH1
or CH2.
4. Press [
X] until SETUP appears and press [ENTER].
5. Press [
X] until ADVAN appears and press [ENTER].
6. Press [
X] until KV/SS appears and press [ENTER].
7. Enter the number of kinematic viscosity/sound speed pairs (2 to
20) by using the arrow keys. Press [
W] and [X] to move the
cursor to desired location and press
[S] and [T] to increase or
decrease the number and press [ENTER].
8. Enter the signal strength value (50.0 to 85.0) by using the arrow
keys. Press [
W] and [X] to move the cursor to desired location
and press
[S] and [T] to increase or decrease the number and
press [ENTER].
IMPORTANT: You must enter the KV vs. SS pairs in descending
order of KV and ascending order of SS. For example,
if pair 1 is KV = 10 centistokes and SS = 62, then
pair 2 must be KV
≤ 10 centistokes and SS ≥ 62.
9. Enter the kinematic viscosity values (0.050 to 500) in descending
order by using the arrow keys. Press [
W] and [X] to move the
cursor to desired location and press
[S] and [T] to increase or
decrease the number and press [ENTER].
10.Repeat Steps 8 and 9 for each pair.
Procedure Options After completing the above steps, the user program returns to the
Advanced Feature window. Do one of the following:
• To continue regular programming, refer to Appendix A, Menu
Maps, to navigate to the desired menu.
• To leave the user program, press [ESC] five times.