Chapter 6. REFERENCE AND SPECIFICATION
98 | ADTS 405 Mk2 Instruction Manual-English © 2015 General Electric Company – All rights reserved.
Flight-line ADTS 405F (indoor and outdoor use):
Pressure/Vacuum Requirements
See Safety and Installation Guide 124M8686
Warm-up
If the ADTS 405 temperature has stabilized within the operating temperature range before
switching on, the test set requires a warm-up period of 15 minutes to achieve the stated accuracy.
Size 442 mm x 755 mm x 332 mm (17½” x 30" x 13")
Weight 29 kg [64 lb]
EMC EN 61326-1 (refer to the declaration of conformity for details)
MIL-STD-461F (Extended environment)
Electrical safety EN61010-1
Power supply Single phase AC in the range
or
100/120/230V ~ 50/60 Hz
115V ~ 400 Hz
500VA
No switching required All automatic
Transient over-voltages up to
the levels of Overvoltage Cat-
egory
II
Operating altitude Up to 15,000ft (4,570 metres)
Extended operating
temperature
-40°C to 55°C (40° to 131°F)
Standard operating temperature -20°C to 50°C (-4° to 122°F)
Storage and shipping temperature -51°C to 70°C (-60° to 158°F)
Operating humidity 0 to 95% RH (non-condensing)
Pollution degree 3
Pressure safety:
Pressure Equipment Directive - class: Sound engineering practice (SEP)
Shock and vibration ingress protection
MIL-PRF-28800 Class 2
Pressure Fittings Ps MS33656-6
Pt MS33656-4