EasyManuals Logo

GE Druck ADTS 405 R/F Mk2 User Manual

GE Druck ADTS 405 R/F Mk2
122 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #80 background imageLoading...
Page #80 background image
Chapter 5. TESTING AND FAULT FINDING
62 | ADTS 405 Mk2 Instruction Manual-English © 2015 General Electric Company – All rights reserved.
5.4 Fault Diagnosis
If a fault occurs, refer to the fault location chart, Figure 5-1 and Table 5-1.
Figure 5-1: Fault Finding Chart
N
Y
F1
N
N
N
Y
Y
SET POWER SWITCH
TO OPERATE
Y
HAND-TERMINAL
FITTED
?
HAND-TERMINAL
FITTED
?
POWER
INDICATOR
ON
?
FRONT PANEL
DISPLAY FITTED
?
N
N
Y
N
Y
F6
F5
Y
STATUS LIGHT
HAND-TERMINAL
BACKLIGHT ON
?
N
POWER-UP SEQUENCE
COMPLETED WITHOUT ERRORS.
IFANY FURTHER ERRORS OCCUR
THE SYSTEM LOGS THE OCCURRENCE
AND DISPLAYSAN ERROR MESSAGE
STATUS LIGHT
FROM NOW ON,
REFER TO ERROR CODES FOR FAULT
FINDING PROCEDURE
IFANY ERRORS OCCUR
THE SYSTEM LOGS THE OCCURRENCE
AND DISPLAYSAN ERROR MESSAGE
TO CONFIRM SERVICEABILITY,
CARRY OUT THE
STANDARD SERVICEABILITY TEST
FUNCTIONALTESTING
COMPLETE
MAKE SURE POWER-UP SEQUENCE
IS COMPLETED WITHOUT ERRORS
N
Y
N
POWER-UP
MESSAGE
?
HAND-TERMINAL
DISPLAY POWER-UP
MESSAGE
?
Power-up sequence
Last Calibration
mm/dd/yy (mdy)
PLEASE WAIT
RPT Transducer
Self Test
PLEASE WAIT
Measuring Ground
Pressures
PLEASE WAIT
Equalising System
Pressures
(Valves May Pulse)
PLEASE WAIT
ALT 0 ft
Leak Measure
CAS 0.0 kts
Leak Measure
WARMUP
SYSTEM STATUS
RED
SYSTEM STATUS
ORANGE
SYSTEM STATUS
GREEN
STATUS LIGHT
F8
F2F9
N
HAND-TERMINAL
FITTED
?
F7
FRONT PANEL
DISPLAY POWER-UP
MESSAGE
?
FRONT PANEL
DISPLAY POWER-UP
MESSAGE
?
STATUS LIGHT
LDK 425 Vx.xx
Display Power Up
PLEASE WAIT
DRUCK
ADTS 405
DK 415
VER x.xx
F2
F7
F9
F3
F9
F2 F10
F4
F9 F8 F2
Y
Y
FLASHING
RED/ORANGE
REDOFFGREEN
FLASHING
RED/ORANGE
REDOFF GREEN
OFF RED FLASHING
RED/ORANGE
FLASHING
RED/ORANGE
REDOFFGREEN

Table of Contents