Operating Limits
© 2015 General Electric Company – All rights reserved. ADTS 405 Mk2 Instruction Manual-English | 3
1000 knot range operating limits
Parameter Max Limits Standard Limits Civil Limits
Min Alt -3,000 ft -3,000 ft -1,000 ft
Max Alt 105,000 ft 80,000 ft 50,000 ft
Min CAS -100 kts 0.0 kts 0 kts
Max CAS 1,000 kts 1,000 kts 450 kts
Min Ps 3.0 mbar 27.615 mbar 115.972 mbar
Max Ps 1355.00 mbar 1,128.029 mbar 1050.406 mbar
Min Qc -1,352.00 mbar -16.303 mbar 0 mbar
Max Qc 2,500.00 mbar 2,490.50 mbar 368.01 mbar
Max Mach 14.97 5 1
Max ROC 1000,000 ft/min 15,000 ft/min 6,000 ft/min
Max Rate CAS 2,000 kts/min 700 kts/min 600 kts/min
Max Rate Ps 10,000.00 mbar/min 200.00 mbar/min 100.00 mbar/min
Max Rate Qc 10,000.00 mbar/min 200.00 mbar/min 100.00 mbar/min
ARINC Limits OFF OFF OFF
Alt Correction 0 ft 0 ft 0 ft