LOCKS
EntelliGuard G
INTRO BREAKER ACCESSORIES TESTS APPENDIX
TRIP UNIT
CATALOGUE
DIMENSIONSERVICE
CONTENT
14th digit
15th digit
16th, 17th & 18th digit 19th digit
Factory Installed
prevision to mount
a Key lock on the
breakers
For Ronis or
Profalux
Key lock
R
For Kirk
Key lock
K
For Castell
type Key lock
C
No prevision
for Key lock
X
Defi nes Installed GT type Electronic Trip Unit
Basic type Code Functionality Code
GT-E
with Ammeter
E
LT, LTDB. ST, STDB
01
LT, LTDB. ST, STDB, GF, GFDB
02
GT-S
with Ammeter
Optional Communication
S
LT, LTDB. ST, STDB, I
06
LT, LTDB. ST, STDB, I, GF, GFDB
07
LT, LTDB. ST, STDB, I, GF, GFDB
* Modbus communication
09
LT, LTDB. ST, STDB, HI, GF, GFDB
03
LT, LTDB. ST, STDB, HI, GF, GFDB
* Modbus communication
05
GT-N
with Measurement
Optional Communication
N
LT, LTDB. ST, STDB, I
08
LT, LTDB. ST, STDB, I, GF, GFDB
10
LT, LTDB. ST, STDB, I, GF, GFDB
+ ZSI on ST and GF
+ Modbus communication
11
LT, LTDB. ST, STDB, HI, GF, GFDB
04
LT, LTDB. ST, STDB, HI, GF, GFDB
+ ZSI on ST and GF
+ Modbus communication
12
Defi nes Installed GT type Electronic Trip Unit
Basic type Code Functionality Code Functionality Code
GT-H
With Measurement,
Relaying and Wave
form capture
Optional, Modbus or
Pro bus
Communication
H
LT+ (C+F),LTDB,ST,STDB.GF+EF,HI
13
LT+ (C+F),LTDB,ST,STDB.GF+EF,I
ZSI on ST, GF & I
+ Modbus Communication
28
LT+ (C+F),LTDB,ST,STDB.GF+EF,HI
+ Modbus Communication
14
LT+ (C+F),LTDB,ST,STDB.GF+EF,HI
+ Profi bus Communication
15
LT+ (C+F),LTDB,ST,STDB.GF+EF,I
ZSI on ST, GF & I
+ Profi bus Communication
29
LT+ (C+F),LTDB,ST,STDB.GF+EF,HI
ZSI on ST, GF & HI
16
LT+(C+F),LTDB,ST,STDB.GFA+EFA,& I
30
LT+ (C+F),LTDB,ST,STDB.GF+EF,HI
ZSHI on ST, GF & HI
+ Modbus Communication
17
LT+(C+F),LTDB,ST,STDB.GFA+EFA, I
+ Modbus Communication
+ Modbus Communication
31
LT+(C+F),LTDB,ST,STDB.GFA+EFA, I
+ Pro bus Communication
32
LT+ (C+F),LTDB,ST,STDB.GFA+EFA,HI
18
LT+ (C+F),LTDB,ST,STDB.GFA+EFA,HI
+ Modbus Communication
19
LT+C+F),LTDB,ST,STDB.
GFA+EFA,IZSI on ST, GFA & I
33
LT+ (C+F),LTDB,ST,STDB.GFA+EFA,HI
+ Profi bus Communication
20
LT+(C+F),LTDB,ST,STDB.
GFA+EFA,IZSI on ST, GFA & I
+ Modbus Communication
34
LT+ (C+F),LTDB,ST,STDB.GFA+EFA,HI
ZSI on ST, GFA & HI
21
LT+(C+F),LTDB,ST,STDB.GFA+EFA, I,
ZSI on ST, GFA & I
+ Pro bus Communication
35
LT+ (C+F),LTDB,ST,STDB.GFA+EFA,HI
ZSI on ST, GFA & HI
+ Modbus Communication
22
LT+ (C+F),LTDB,ST,STDB.I
+ Modbus Communication
36
LT+ (C+F),LTDB,ST,STDB.I
23
LT+ (C+F),LTDB,ST,STDB.GF+EF,I
24
LT+ (C+F),LTDB,ST,STDB.I
+ Pro bus Communication
37
LT+ (C+F),LTDB,ST,STDB.GF+EF,I
+ Modbus Communication
25
LT+(C+F),LTDB,ST,STDB.GF+EF,HI
+ Pro bus Communication
38
LT+ (C+F),LTDB,ST,STDB.GF+EF,I
+ Profi bus Communication
26
LT+C+F),LTDB,ST,STDB.GFA+EFA,HI
ZSI on ST, GFA & HI
+ Pro bus Communication
39
LT+ (C+F),LTDB,ST,STDB.GF+EF,I
ZSI on ST, GF & I
27
Defi nes
instruction
manual language
English
German
Polish
A
English
Dutch
French
B
English
Portuguese
Spanish
E
Factory Installed
prevision to mount
a Cable interlock
between breakers
Mechanical
Interlock -
Type A
1
Mechanical
Interlock -
Type B
2
Mechanical
Interlock -
Type C
3
Mechanical
Interlock -
Type D
4
No prevision
for Breaker
interlock
X
G BX H 23