Appendix B. Modbus Communication
48 PanaFlow™ XMT1000 User’s Manual
TBD Dout2 Int RW
2500 2500 Operator eDout2_
PulseTestValue
Output_2 Test Pulse Value unitless RW 4 INT32
2502 Operator eDout2_
FreqFullFreq
Output_2 Frequency Full
Frequency
6RW4INT32
2504 Operator eDout2_FreqTe
stValue
Output_2 Test Frequency
Val ue
6RW4INT32
2506 Operator eDout2_
FreqErrValue
Output_2 Frequency Error
Handling Value
6RW4INT32
2580 2580 Operator eDout2_Type Output_2 type unitless RW 4 INT32
2582 Operator eDout2_
PulseUnit
Output_2 Pulse Value Unit
Code
unitless RW 4 INT32
2584 Operator eDout2_
PulseErr
Output_2 Pulse Error
Handling
unitless RW 4 INT32
2586 Operator eDout2_
FreqAddress
Output_2 Frequency
Measument Register
Address
unitless RW 4 INT32
2588 Operator eDout2_
FreqErr
Output_2 Frequency Error
Handling
unitless RW 4 INT32
258A Operator eDout2_
FreqUnit
Output_2 Frequency Unit
code
unitless RW 4 INT32
258C Operator eDout2_
AlarmState
Output_2 Alarm State unitless RW 4 INT32
258E Operator eDout2_
AlarmType
Output_2 Alarm Type unitless RW 4 INT32
2590 Operator eDout2_
AlarmAddress
Output_2 Alarm
Measument Register
Address
unitless RW 4 INT32
2592 Operator eDout2_
AlarmUnit
Output_2 Alarm Unit code unitless RW 4 INT32
2594 Operator eDout2_
AlarmTest
Output_2 Test Alarm unitless RW 4 INT32
2596 Operator eDout2_
ControlState
Output_2 Control Ouput
State
unitless RW 4 INT32
2598 Operator eDout2_
ControlType
Output_2 Control Ouput
Type
unitless RW 4 INT32
259A Operator eDout2_
ControlAddress
Output_2 Control Ouput
Measument Register
Address
unitless RW 4 INT32
259C Operator eDout2_
ControlUnit
Output_2 Control Ouput
Unit code
unitless RW 4 INT32
259E Operator eDout2_
ControlTest
Output_2 Test Control
Ouput
unitless RW 4 INT32
25A0 Operator eDout2_
PhaseShift
Output_2 Phase Shift unitless RW 4 INT32
25A2 Operator eDout2_
TestMode
Output_2 Test Mode unitless RW 4 INT32
Table 6: XMT1000 Modbus Register Map - Revision 4.19 (cont.)
Reg #
in Hex
Access
Level
Register ID Description Units RO/RW
Size in
Bytes
Format

Table of Contents