PanaFlow™ XMT1000 User’s Manual 61
Appendix D. Foundation Fieldbus Communication
D.3 Specifications
D.3.1 General
D.3.2 Physical
D.3.3 Communication
Manufacturer Name: GE
Manufacturer ID (Hex): 004745
Model: XMT1000
Device Type: 0010
FF Device Revision: For latest, see Fieldbus Foundation website
FISCO Compliant: Yes
Hazardous Location Certs: See drawing 752-584
ITK Revision: 6.2
Protocol: H1
Protocol Baud (bps): 31.25k
DD and CFF Files: For latest, see Fieldbus Foundation website
Meter Programmable through FF: Yes
Polarity Sensitive (Yes/No): No
Quiescent Current Draw (mA): 26
Working Voltage: 9-32 VDC
Stack Manufacturer: Softing AG
Backup LAS Capable: Yes*
Total Number of VCRs: 24
Fixed VCRs for Configuration: 1
*LAS means Link Active Scheduler. It can schedule a network if the main LAS fails.

Table of Contents