EasyManuals Logo

GE PanaFlow XMT1000 User Manual

GE PanaFlow XMT1000
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #73 background imageLoading...
Page #73 background image
PanaFlow™ XMT1000 User’s Manual 61
Appendix D. Foundation Fieldbus Communication
D.3 Specifications
D.3.1 General
D.3.2 Physical
D.3.3 Communication
Manufacturer Name: GE
Manufacturer ID (Hex): 004745
Model: XMT1000
Device Type: 0010
FF Device Revision: For latest, see Fieldbus Foundation website
FISCO Compliant: Yes
Hazardous Location Certs: See drawing 752-584
ITK Revision: 6.2
Protocol: H1
Protocol Baud (bps): 31.25k
DD and CFF Files: For latest, see Fieldbus Foundation website
Meter Programmable through FF: Yes
Polarity Sensitive (Yes/No): No
Quiescent Current Draw (mA): 26
Working Voltage: 9-32 VDC
Stack Manufacturer: Softing AG
Backup LAS Capable: Yes*
Total Number of VCRs: 24
Fixed VCRs for Configuration: 1
*LAS means Link Active Scheduler. It can schedule a network if the main LAS fails.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE PanaFlow XMT1000 and is the answer not in the manual?

GE PanaFlow XMT1000 Specifications

General IconGeneral
BrandGE
ModelPanaFlow XMT1000
CategoryTransmitter
LanguageEnglish

Related product manuals