28 ADP200 • Quick installation guide - Specifications and connection
7.1 Power section
7.1.1 Cable cross-sections
Size
Terminals: L1 - L2 - L3 - BR - C1 - C - D - U - V - W
Maximum cable cross-section
(flexible conductor)
Minimum cable cross-section
(flexible conductor)
Recommended
stripping
Recommended
terminal
Tightening
torque (min)
(mm
2
) AWG (mm
2
) AWG (mm) (mm) (Nm)
2075 6 8 0.2 24 10 None / pin 0.7 ... 0.8
2110 6 8 0.2 24 10 None / pin 0.7 ... 0.8
3150 16 6 0.75 18 14 None / pin 1.7 ... 1.8
3185 16 6 0.75 18 14 None / pin 1.7 ... 1.8
3220 16 6 0.75 18 14 None / pin 1.7 ... 1.8
Terminals: L1 - L2 - L3 - BR1 - BR2 - C - D - U - V - W
4300 35 2 0.5 20 18 None / pin 2.4 ... 4.5
4370 35 2 0.5 20 18 None / pin 2.4 ... 4.5
4450 35 2 0.5 20 18 None / pin 2.4 ... 4.5
5550
95
(BR1/BR2=50)
4/0
(BR1/BR2=1/0)
10 4/0
23
(BR1/BR2=27)
None / pin
14
(BR1/BR2=10)
5750 95 4/0 10 4/0 23 None / pin 14
Note! The power terminal strip is extractable on sizes 2075 ... 3220. The EM terminal strip is extractable on all mechanical sizes.
Size
Terminals: BR1 - BR2
Maximum cable cross-section
(flexible conductor)
Minimum cable cross-section
(flexible conductor)
Recommended
stripping
Recommended
terminal
Tightening
torque (min)
(mm
2
) AWG (mm
2
) AWG (mm) (mm) (Nm)
5S550 / 5S750 25
2
10 10
19
None 4.5
Sizes
Terminals: L1 - L2 - L3 - C - D - U - V - W
Cable cross-section
Lock screw diameter
Recommended
terminal
Tightening torque (min)
(mm
2
) AWG (mm) (mm) (Nm)
5S550 / 5S750 50 1/0 M10 Eyelet - Fork 25
Size
Terminals: on structural work
Cable cross-section
Lock screw diameter
Recommended
terminal
Tightening torque (min)
(mm
2
) AWG (mm) (mm) (Nm)
3220
Same as the maximum cross-section used for the
power terminal strip
M5 Eyelet - Fork 6
4300 16 6 M6 Eyelet - Fork 10
4370 16 6 M6 Eyelet - Fork 10
4450 16 6 M6 Eyelet - Fork 10
5550 50 1/0 M6 Eyelet - Fork 10
5750 50 1/0 M6 Eyelet - Fork 10
5S550 / 5S750 50 1/0 M10 Eyelet - Fork 25
Note! The power terminal strip is extractable on sizes 2055 ... 3110.
Note! The minimum cross-section for both ground connections must comply with EN61800-5-1 prescriptions. Always ground both points on structural steel.