ADP200 • Quick installation guide - Specifications and connection 55
8.3.3 Scanning of the parameters
01 MONITOR
02 DRIVE INFO
03 STARTUP WIZARD
04 DRIVE CONFIG
05 REFERENCES
01 MONITOR
01.01 PAR: 250
Output current
0.00 A
0%
01 MONITOR
01.24 PAR: 1400
Di
g
ital output X mon
00000000000000
01 MONITOR
01.02 PAR: 252
Output voltage
0 V
0%
8.3.4 List of the last parameters modied
Pressing the CUST key, a list containing the last 10 parameters modied is accessed. One parameter is displayed at a
time and the list can be scrolled using the ▲ and ▼ keys.
To exit this list, press the ► key.
8.3.5 Parameter modication
To enter parameter modication mode, press the E key when the parameter to be modied is displayed.
To save the value of the parameter, following modication, press the E key again.
Note! To save permanently, see paragraph 8.4.
To exit modication mode without saving the value, press the ESC key.
The operations to be carried out to modify the value depend on the type of the parameter, as described below.
Note! For further information about the type of parameters displayed, see paragraph 8.2.2.
Numeric parameters
16 MOTOR DATA
17 ENCODER CONFIG
18 SPEED REG GAINS
19 REGULATOR PARAM
20 TORQUE CONFIG
16
MOTOR DATA
16.01 PAR: 2000
Rated voltage
175 V
Def: 400
E
16
MOTOR DATA
16.01 PAR: 2000
Rated voltage
000000175 v
Def: 400
When E is pressed to access modication mode, the cursor is activated on the digit corresponding to the unit.
Using the ◄ and ► keys, the cursor can be moved to all the digits, including trailing zeros that are normally not
displayed.
With the ▲ and ▼ keys, the digit under the cursor is increased or decreased.
Press E to conrm the modication or ESC to cancel.
Binary parameters (BIT type)
The parameter may assume only two states which are indicated as On-Off or 0-1.
13 DIGITAL OUTPUTS
14 ANALOG INPUTS
15 ANALOG OUTPUTS
16 MOTOR DATA
17 ENCODER CONFIG

x9
13 DIGITAL OUTPUTS
13.10 PAR: 1430
Di
g
out 1X inversion
OFF
E
13 DIGITAL OUTPUTS
13.10 PAR: 1430
Di
g
out 1X inversion
OFF
13 DIGITAL OUTPUTS
13.10 PAR: 1430
Di
g
out 1X inversion
ON
Press E to activate modication mode. The entire line is displayed in reverse. Use the ▲ and ▼ keys to move from one
state to another. Press E to conrm the modication or ESC to cancel.

Table of Contents