ADP200 • Quick installation guide - Specifications and connection 51
• Modifying Enum values
When you press Enter on an Enum value, the rst digit on the right ashes.
Use the arrow keys to scroll all the enum values of that parameter cyclically.
Press Enter again to accept the value.
Press Prg to reject the value and restore the previous value.
E.g.:
Synchronous list, Menu 4.15 – DRIVE CONFIG, PAR 578 Language select (default = [0] English)
04.88.
Enter
(x14)
05.78.
Enter
00.80.
Enter
00. 00.
00. 01.
Enter
00. 81.
• Modifying Link values
When you press Enter on a Link value, the rst digit on the right ashes.
Use the arrow keys to scroll all the links in the list associated with that parameter cyclically.
Press Enter again to accept the value.
Press Prg to reject the value and restore the previous value.
E.g.:
Synchronous list, Menu 13 – DIGITAL OUTPUTS, PAR 1410 Dig output 1X src (default = [6000] Null)
13. 88.
Enter
14. 10.
Enter
60.00.
Enter
60.00.
60. 02.
Enter
60. 02.
• Modifying On-Off values
Boolean values are displayed with the words On and Off.
When you press Enter, the rst digit on the right ashes.
Use the up and down arrow keys to change the value cyclically from On to Off.
Press Enter again to accept the value.
Press Prg to reject the value and restore the previous value.
E.g.:
Synchronous list, Menu 4.14 – DRIVE CONFIG , PAR 576 Display backlight (default = [0] OFF)
04.88.
Enter
(x13)
85.76.
Enter
8o. FF.
Enter
8o. FF.
88.on.
8.2.4 Error messages when modifying a parameter
When accepting a value, if you hold Enter down or press Enter on the last digit, an error message may be displayed:
RO Read only parameter, if Enter is pressed on a read only parameter
ORNG Value outside range
DRVE Drive enabled, if you are trying to modify a parameter than cannot be modied with the drive enabled
ERR Other errors
Press Prg to clear the error message.
8.2.5 Displaying and closing Messages
Note ! Some messages may be displayed on the integrated keypad at start-up or during operation. The list of messages is provided in chapter "10.3 Messages" .
Sub-codes are not shown on the integrated keypad.
Press Prg to exit a message if it does not close automatically.
8.2.6 Displaying and resetting Alarms
Note ! The alarms are shown on the display of the integrated keypad with the abbreviated text shown in brackets "[XXX]" in chapter "10.1 Alarms" on page 88 .
Active alarms are displayed by a ashing indicator.