70 ADP200 • Quick installation guide - Specifications and connection
Step 4 - Setting encoder parameters (Standard card EXP-RES-I1-ADP)
The incorrect conguration of the encoder tension can permanently damage the device; therefore, it is advisable to
check the values on the encoders specication plate.
03 STARTUP WIZARD
Set encoder param?
E=Yes Down=Next
E
x 4
SEQ
SEQ . 04 PAR: 2116
Resolver pole pairs
1
Def: 1
E
SEQ
SEQ . 04 PAR: 2116
Resolver pole pairs
000000001
Def: 1
2
E
SEQ
SEQ . 04 PAR: 2118
Resolver frequency
5000 Hz
Def: 5000
E
SEQ
SEQ . 04 PAR: 2118
Resolver frequency
000005000 Hz
Def: 5000
5001 Hz
4999 Hz
E
Proceed to the next step.
Step 5 - Encoder phasing (Standard card EXP-RES-I1-ADP)
ADP200 drives have a command to start automatic phasing of the resolver.
Phasing must be repeated whenever:
- the drive is replaced (alternatively, download parameters taken from previous drive)
- the motor is replaced
- the encoder is replaced
Note ! For more information see parameters 17.23 PAR 2190 Autophase rotation and 17.24 PAR 2192 Autophase still on "Functions description and parameters
list" manual (ADP200 Vector inverter for Hybrid injection molding machines).
See section A.3.2 Phasing in the Appendix for further information.
Step 5A - Encoder phasing with rotating motor
03 STARTUP WIZARD
Run phasing rot?
E=Yes Down=Next
E
03 STARTUP WIZARD
Close Enable in
p
ut
Esc=Abort
SEQ
SEQ . 01 PAR: 2190
Autophase rotation
Press E to exe
c
ute
E
Auto
phase
Progress 0%
(1) (2) (3) (4)
Auto
phase
Progress 10%
Press ESC to abort
Auto
phase
Progress 100%
Auto
phase
Done
03 STARTUP WIZARD
Open Enable input
(5)
Step 5B - Encoder phasing with still motor
03 STARTUP WIZARD
Run phasing still?
E=Yes Down=Next
E
03 STARTUP WIZARD
Close Enable still
Esc=Abort
SEQ
SEQ . 01 PAR: 2192
Autophase still
Press E to exe
c
ute
E
Auto
phase
Progress 0%
(1) (2) (3) (4)
Auto
phase
Progress 10%
Press ESC to abort
Auto
phase
Progress 100%
Auto
phase
Done
03 STARTUP WIZARD
Open Enable input
(5)