ADP200 • Quick installation guide - Specifications and connection 81
Index Error message shown on
the display [on the inte-
grated keypad]
Sub-code Description
13-14
Measurement of DTS internal voltage outside accepted range.
Solution: check connection between drive and motor.
If correct, the drive is faulty, contact the Gefran technical support centre.
15 - 16 -17
LS leakage inductance value outside accepted range.
Solution: Perform autotuning once more, if the problem persists, contact the Gefran technical support centre.
18-19
Measurement of Im magnetising current outside accepted range.
Solution: Perform autotuning once more, if the problem persists, contact the Gefran technical support centre.
20-21
Measurement of Rr rotor resistor outside accepted range.
Solution: Perform autotuning once more, if the problem persists, contact the Gefran technical support centre.
30
The Enable was not given or removed in time during the phasing procedure.
Solution: Repeat the phasing procedure and check the connection of the enable signals.
Solution: If the message appears with a value other than 0, follow the instructions supplied for each particular case and repeat Autotune. This should
be performed using the wizard function available from the keypad (STARTUP WIZARD) and the Tool software on the PC.
Pay attention to all motor plate data parameters, especially:
- Rated speed, Motor rated speed in rpm.
- Rated frequency, Motor rated frequency in Hz
- Pole pairs, Motor pole pairs
Take care to set the Rated speed parameter to the synchronous speed.
If the problem persists even after following the instructions supplied, confirm the values of the motor plate data parameters, execute the Take param-
eters command but not Autotune.
6 Power config Condition: may occur during recognition of power cards. If this message is displayed, it is not possible to drive the motor.
[PC] 0020H-32 The power card is configured for a drive that is incompatible with the regulation card
0021H-33 The configuration of the power card is not compatible with the regulation card
0017H-23 The configuration required is not available on the power card
Solution: Download the correct configuration on the power card
7 Save par failed Condition: during transfer of the parameters from the drive to the memory of the keypad
[FAIL] XXXXH-X Error during saving of parameter due to Communication error
0025H-37 The data saved on the keypad are not valid
0026H-38 Incompatible drive series
0027H-39 Incompatible software version
0028H-40 Incompatible drive size
0029H-41 Error during saving of parameters on the drive
Solution:
8 Load par failed Condition: during transfer of the parameters from the memory of the keypad to the drive
9 Load par incomplete 0H-0 Communication error
[FAIL] 0023H-35 Communication error
0024H-36 Communication error
0025H-37 The data saved on the keypad are not valid.
No parameter is transferred from the keypad to the drive
0026H-38 Incompatible drive series.
No parameter is transferred from the keypad to the drive
0027H-39 Incompatible software version.
All the parameters present in the memory of the keypad have been transferred to the drive. The set of parameters transferred refers to
a drive with a different firmware version; therefore, certain parameters may not be updated.
0028H-40 Incompatible drive size.
All the parameters present in the memory of the keypad (excluding those that depend on the size of the drive), have been transferred to
the drive. The parameters that depend on size maintain their original value.
0029H-41 Error during saving of parameters on the drive.
All the parameters present in the memory of the keypad have been transferred to the drive. The transfer of one or more parameters has
caused an “out of range” error, or one or more parameters does not exist. At the end of transfer, one or more parameters may not have
been updated.
002AH-42 PLC application release and version not compatible.
All parameters in the keypad memory have been transferred to the drive.
The transferred set of parameters relates to a drive with a PLC application in which the version and release of the application are differ-
ent. As a result some of the PLC application parameters may not be updated.
002BH-43 PLC application not compatible.
All the parameters in the keypad memory except those relating to the PLC application have been transferred to the drive.
The transferred set of parameters relates to a drive with a different PLC application. As a result none of the PLC application parameters
are updated.
Solution: Recover a set of parameters from a compatible drive (model and size)
10 Options config error Condition: may occur at drive start-up, during recognition of the optional cards installed
[OPTC] 0001H-1 Non-permissible optional card in slot 1
0002H-2 Non-permissible optional card in slot 2
0004H-4
0010H-16 Conflict slot 1 with slot 2
0020H-32
0040H-64
Solution: Remove the optional cards from the incorrect slots and insert them in the correct slots