ADP200 • Quick installation guide - Specifications and connection 87
Description Features
Type Current differential
Input current 0 (4) mA to 20 mA
Input R 500 Ω
Resolution 12 Bits (11 + sign)
Precision 1% of full scale
Isolation NO
(*) Select input V/I (V=OFF, I=ON)
● Selection of Voltage/Current at analog inputs / output and Pressure sensor
In addition to programming the parameter (PAR 1602 - 1652 - 1898) the position of switches P3-P4-P5 on the I/O card
must also be checked.
P2 P3
P4
P5
OFF
ON
I
V
Jumper (I/O card) Parameter combination
P2 AIS : Pressure sensor input ON = I OFF = V 1502 Analog inp 1 type
P3 AI1: Analog input ON = I OFF = V 1602 Analog inp 1X type
P4 AI2: Analog input ON = I OFF = V 1652 Analog inp 2X type
P5 AI2: Analog output See figure 1898 Analog out 2X type
● Analog output (AO)
Description Features
Type Single-ended in voltage
Output voltage 0 to 10V
Load 5 mA @ ± 10 V - Rl = 2.2 kΩ
Resolution 12 Bits
Precision 1% of full scale
Isolation NO
Description Features
Type Single-ended in current (only output 2)
Output current 0 (4) mA to 20 mA
R load 500 Ω
Resolution 12 Bits
Precision 1% of full scale