EasyManua.ls Logo

gefran ADP200

gefran ADP200
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ADP200 • Quick installation guide - Specifications and connection 95
EXP-SE-I1R1F2-ADL
Incremental Sinusoidal Encoder (SE).
EXP-SE-I1R1F2-ADL
XER
XE
BR
-
BR
+
AR
-
AR
+
DI
F2
DI
F1
DI
CM
Z
-
Z
+
B
-
B
+
A
-
A
+
0VE
out
+VE
out
20 21 22 23 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Channels ������������������������������� A+ A-, B+ B-, Z+ Z-, differential.
Management of loss of encoder signals
Max frequency �������������������������� 200 kHz (check the number of encoder impulses according to the maximum speed)
Number of impulses ���������������������� min 128, max 16384 (default 1024)
Electrical interface ������������������������ Channels A/B 0,8V ≤ Vpp ≥ 1,2V (typ. 1,0V) − Channel Z 0,2V ≤ Vpp ≥ 0,8V
Load capacity ��������������������������� 8mA @ 1.0Vpp (Zin 120Ω)
Programmable internal power supply ���������� min +5.2 V, max +6.0 V (default + 5.2 V) − Imax 150 mA.
See table (1)
Cable length ���������������������������� max 50m
INCREMENTAL SINUSOIDAL ENCODER (SE)
A-
A+
0VE out
+VE out
Z-
Z+
B-
B+
8
9
10
11
12
13
14
15
1
2
3
4
5
6
7
(*)
XE
(*) Connection of shielding, see gure 7.2.4

Table of Contents