ADP200 Application PID-IMM User Manual Pag. 47 of 80
This menu contains pressure and flow (speed) references and pressure feedback source assignment, as
well as local settings useful for test purpose (manual references and feedback).
Signals sources can be selected from standard list containing analog inputs, fieldbus process data and pads.
Ipa
Parameter Name
Unit
Type
Default
Min
Max
11054 Manual Press Ref bar FLOAT 30 0.00 1000.00
11056 Manual Speed Ref rpm FLOAT 100 0.00 4000.00
11058 Manual FeedBack bar FLOAT 0 - -
11060 Pres Fbk source (!) - INPUT SELECT 1500 0.00 -
11062 Pressure Ref Source - INPUT SELECT 1600 - -
11064 Flow Ref Source - INPUT SELECT 1650 - -
11066 Press Ramp Acc Coef s FLOAT 0.1 0.00 100.00
11068
Speed Ramp Acc Coef
s
FLOAT
0.1
0.00
100.00
11070
Reference Variation
-
FLOAT
0
0.00
0.20
11072
Conv Div Cmd Source
-
DIG_PAR
0
-
-
11074
Diverg Cmd Dig Val
-
BOOL
OFF
-
-
11076
Fieldbus Press Ref (Expert)
bar
FLOAT
30
0.00
1000.00
11078
Fieldbus Speed Ref (Expert)
rpm
FLOAT
100
0.00
4000.00
11080
Press Ramp Dec Coef
s
FLOAT
0.1
0
100
11082
Speed Ramp Dec Coef
s
FLOAT
0.1
0
100
Manual Speed Ref Speed reference digital parameter for local setting .
Manual Press Ref Pressure reference digital parameter for local setting.
Manual FeedBack Pressure feedback digital parameter for local setting (test purpose).
Pres Fbk Source (!) Selection of source for pressure feedback signal.
Assigned from:
0 = Digital Param: source is local parameter.
1500 = Analog Input S: source is analog input port S = sensor (T2:70-71-72)
1600 = Analog Input 1: source is analog input 1 (T2:42-43)
1650 = Analog Input 2: source is analog input 2 (T2: 40-41)
3700 = Pad 1 source is system pad1 (see menu FUNCTIONS / PADS).
3702 = Pad 2 source is system pad2
…….
…….
3730 = PAD16: source is system pad16 (see menu FUNCTIONS / PADS).
4024 = Fieldbus M->S1 Real source is fieldbus process data channel 1.
4034 = Fieldbus M->S2 Real source is fieldbus process data channel 2
…….
…….
4094 = Fieldbus M->S8 Real source is fieldbus process data channel 8
Note: The following selection are not used for Pres Fbk Source (!) selection
11554 = PLCPressRef: source of Press. Ref. is external CANopen master
(Convergent mode)
11556 = PLCSpeedRef: source of Speed Ref. is external CANopen master
(Convergent mode)
This two parameters are used only in case of multi-pump Master Drive with PID
IMM/CAN/[11626]CANMPacrive = ON
11560 = DivPressRef: source of Press. Ref. is external CANopen master
(Divergent mode)