38
Notes: 1. Setting F25 to “010” [50 Hz] will automatically set F05 to “001” [50 Hz] and F06 to “050” [50 Hz]. Setting F25 to “020” [60 Hz] will automatically set F05 to “004” [60 Hz]
and F06 to “060” [60 Hz]. 2. For Preset Speed #3, set F19 to “002”, F20 to “006”, and connect Terminals 6 and 7 of Terminal Block TM2 together. *Settings of F01, F02, F04, F06,
and F07 can be changed while the drive is in the run mode.
Page
Number
45
45
45
46
46
47
47
47
48
48
48
48
51
51
Factory
Setting
8.0
100
002
005
003
000
000
0
000
20.0
30.0
001
—
—
Function Range/Code
0.0 - 20.0
1 - 200
001: Jog 004: Coast-to-Stop
002: Preset Speed #1 005: Reset
003: Rapid Stop 006: Preset Speed #2
001: Jog 004: Coast-to-Stop
002: Preset Speed #1 005: Reset
003: Rapid Stop 006: Preset Speed #2
001: Run 002: Frequency Reached 003: Fault
000: Enable Reverse Run 001: Disable Reverse Run
000: Enable Auto Restart 001: Disable Auto Restart
0 - 5
010: Reset Drive for 50 Hz Constant Torque Motor Operation
020: Reset Drive for 60 Hz Constant Torque Motor Operation
0.0 - 200
0.0 - 200
000: Enable Automatic AC LIne Start
001: Disable Automatic AC LIne Start
—
—
Function Description
DC Injection Brake Level (% Bus Voltage)
Electronic Motor Overload Protection (I
2
t) (% Full Load)
Multifunction Input Terminal 6
2
Multifunction Input Terminal 7
2
Multifunction Output Relay (Terminals 1, 2)
Reverse Enable/Disable
Auto Restart (After a Fault Has Cleared)
Number of Auto Restart Attempts
Reset Drive to Factory Settings
1
Preset Speed #2 Frequency (Hz)
Preset Speed #3 Frequency (Hz)
2
Automatic AC Line Start
CPU Program Version
Logs Last 3 Faults that Occurred
Function
Number
F17
F18
F19
F20
F21
F22
F23
F24
F25
F26
F27
F28
F29
F30
TABLE 15 – PROGRAMMABLE FUNCTIONS SUMMARY LIST (Continued)
Sec. VIII – Drive Operation (Cont.)