Provides essential safety precautions and warnings for using the Geodesic Sensor Net.
Outlines the fundamental principles of connecting and operating the GSN.
Details the procedure for replacing electrodes on the GSN 200.
Covers fundamental safety warnings regarding electrical connections and supervision.
Provides precautions regarding potential skin irritation during prolonged use.
Warns against cross-contamination between subjects using shared towels.
Emphasizes inspecting and maintaining cables and connectors to prevent electrical shock.
Provides detailed steps for cleaning, rinsing, and disinfecting the GSN.
Outlines criteria for selecting subjects and preparing their hair for GSN application.
Covers preparations before applying the GSN, including subject preparation.
Provides step-by-step instructions for preparing HydroCel Saline and HydroCel HS.
Explains how to perform head measurements for calculating Net size.
Provides comprehensive steps for applying the GSN to the subject's head.
Details the process of soaking the GSN sensors in electrolyte solution.
Explains the correct hand positioning for stretching and applying the Net.
Covers making initial sensor and strap adjustments for comfort and fit.
Guides on checking sensor placement, symmetry, and making final adjustments.
Provides instructions for filling pedestals with HydroCel HS for HCGSNs without sponges.
Details the procedure for safely removing the GSN from the subject's head.
Outlines the standard rinsing procedure applicable to all GSN models.
Describes additional rinsing steps required for HCGSNs with HydroCel HS.
Provides instructions for disinfecting the GSN using Control III solution.
Provides instructions for replacing electrodes in the GSN 200 model.
Lists the necessary tools for performing electrode replacement.
Details the steps to disassemble the connector and remove the electrode.
Guides on how to install a new electrode into the sensor housing.
Details the steps for reassembling the connector after electrode replacement.
Provides instructions for replacing sponges in the HCGSN model.
Guides on correctly positioning a new sponge in the pedestal.
Lists key practices to prolong the useful life of the GSN.
Discusses sources of noise and methods to reduce it in EEG recordings.
Describes common characteristics of poor quality EEG signals and their potential causes.
Provides guidelines to diagnose and resolve issues related to Net preparation and application.
Addresses problems arising from connection issues or faulty sensor connectivity.
Offers guidelines for determining if an individual sensor is faulty.