EasyManuals Logo

GEZE ECturn Wiring Diagram

GEZE ECturn
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #19 background imageLoading...
Page #19 background image
ECturn/ECturn Inside
19
Push And Go
9 Push And Go
WARNING
Danger of injury due to crushing and shearing!
During an activated Push And Go function door handles can form potential danger points.
à The Push And Go function allows activation of the drive without contact sensors being used.
à When the Push And Go function is set, the drive opens the door automatically as soon as the door leaf is moved
manually out of the closing position.
à The opening angle for use of automatic opening can be adjusted.
à When a safety sensor open is connected, the SIO can block the opening of the door if the sensor detects
an obstacle in the opening direction.
An activating angle that is set too small can result in undesired automatic opening of the door.
X
Set the parameter
pU
(Push And Go) to
00
, for “no Push And Go” or to the required opening angle for the start
of automatic opening.
10 Push to Close
WARNING
Danger of injury due to crushing and shearing!
Push To Close can lead to undesired automatic closing of the door on exterior doors or doors that can be moved
unintentionally towards the closing position.
Depending on the setting, the Push To Close function allows the door to be set manually from the mode of op-
eration DO to AU, or to interrupt an expiring hold-open time in AU or NA and to make the door close.
When the Push To Close function is set, the drive closes the completely open door if it is moved manually by
approx. 10° towards the closing position.
When a safety sensor “close” is connected, this can block the closing of the door if the sensor detects an obstacle.
X
Set the parameter
pC
(Push To Close):
à
00
– no “Push To Close”
à
01
– “Push To Close” in AU or NA (cancel hold-open time, switch function)
à
02
– “Push To Close” in DO, drive changes to mode of operation AU
à
03
“Push To Close” in AU, NA or DO (cancel hold-open time, switch function or change to mode of operation AU).
Setting values
02
and
03
cannot be used at the same time as a manual programme switch (MPS).

Table of Contents

Other manuals for GEZE ECturn

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GEZE ECturn and is the answer not in the manual?

GEZE ECturn Specifications

General IconGeneral
BrandGEZE
ModelECturn
CategoryDoor Opening System
LanguageEnglish

Related product manuals