ECturn/ECturn Inside
37
Commissioning and service
X
Exit the service menu:
à With S1, S2: Simultaneously press buttons S1 and S2 longer than 2 s.
à With DPS: Press the hidden service button and button at the same time.
After learning, the AU mode of operation is set, the mode of operation LED lights up green, interrupted by 2 ash
pulses (1Hz).
à With DPS: Unplug DPS
X
Close door leaf completely.
X
Actuate drive (K, KB or radio remote control).
The door opens slowly to the open position. Afterwards the door then closes again with slower speed.
Flashing of the mode of operation LED stops as soon as the drive was able to move through the taught opening
angle range.
X
Teach the GC338 sensor strips.
X
Following successful teaching of the sensor strips, activate the safety sensors by parameter setting on the
control unit:
à
s1
(safety closing) to
01
for “SIS” or
02
for “SIS and K”
à
s3
(safety opening) to
01
for “SIO”
à
Te
(testing) to
01
, for “testing with 24V”
X
Terminating commissioning:
à Check function and detection areas of all contact sensors.
à Check function and detection areas of the safety sensors for monitoring opening and closing. Check sensor
strips of each individual sensor module.