EasyManua.ls Logo

Gill Instruments 1561-PK-020 - Horizontal Wind Direction; Mode 3-ASCII, UVW, Polled

Gill Instruments 1561-PK-020
69 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
WindMaster and WindMaster Pro 1561-PS-0001. Issue 11 February 2017
________________________________________________________________________________________________________________________
38
Horizontal wind direction
Indicated in degrees, from 0 to 359, with respect to the WindMaster North marker.
In fixed field mode and when the wind speed is below 0.05 metres/sec, the direction will not be calculated, but the last
calculated direction above 0.05 m/s will be output (the threshold of 0.05 m/s is the default setting; it is user-
configurable).
(b) Mode 2 (High Resolution Shown J2)
ASCII, Polar+W, Continuous, Speed of Sound On, Sonic Temp On, [Analogue inputs On], PRT On
<STX><ID>,DDD.D,MMM.MMM,±WWW.WWW,U,±CCC.CC,TTT.TT,SS,[±1.1111,±2.2222,±3.3333
±4.4444],PP.PPC,<ETX>CC<CR><LF>
Where:
<STX> - Start of string character (ASCII value 2)
<ID> - Anemometer Identification (A-Z)
DDD.D - Direction in degrees
MMM.MMM - Wind Magnitude
±WWW.WWW- ‘W’ axis velocity 0.001ms
-1
units
U - Units (M=m/s)
±CCC.CC - Speed of Sound in 0.01ms
-1
units
±TTT.TT - Sonic Temperature in Degrees C.
SS - Status data (Codes 00 to 0B)
±1.1111 - Analogue input 1 in volts
±2.2222 - Analogue input 2 in volts
±3.3333 - Analogue input 3 in volts
±4.4444 - Analogue input 4 in volts
±PP.PPC - PRT temperature in degrees C, e.g. +23.13deg C output as +23.13C in the string.
<ETX> - End of string character (ASCII value 3)
CC - Checksum of all Characters between <STX> and <ETX> (HEX byte)
<CR><LF> - Carriage Return and Line Feed
7.3. Mode 3–ASCII, UVW, Polled.
Mode 3 (Normal Resolution Shown)
ASCII, UVW, Polled, Speed of Sound On, Sonic Temp On, [Analogue inputs On], PRT On
<STX><ID>,±UUU.UU,±VVV.VV,±WWW.WW,U,CCC.CC,
TTT.TT,SS,[±1.1111,±2.2222,±3.3333±4.4444],PP.PPC,<ETX>CC<CR><LF>
Where:
<STX> - Start of string character (ASCII value 2)
<ID> - Anemometer Identification (A-Z)
±UUU.UU - ‘Uaxis velocity 0.01ms
-1
units
±VVV.VV - ‘V’ axis velocity 0.01ms
-1
units
±WWW.WW - ‘W’ axis velocity 0.01ms
-1
units
U - Units (M=m/s, N=knots, P=mph, K=kph)
±CCC.CC - Speed of Sound in 0.01ms
-1
units
±TTT.TT - Sonic Temperature in Degrees C.
SS - Status data (Codes 00 to 0B)
±1.1111 - Analogue input 1 in volts
±2.2222 - Analogue input 2 in volts
±3.3333 - Analogue input 3 in volts
±4.4444 - Analogue input 4 in volts
±PP.PPC - PRT temperature in degrees C, e.g. +23.13deg C output as +23.13C in the string.
<ETX> - End of string character (ASCII value 3)
CC - Checksum of all Characters between <STX> and <ETX> (HEX byte)
<CR><LF> - Carriage Return and Line Feed

Table of Contents